Table I.

Per‐subject M1 depths

Subject M1 depth (mm)* Threshold (E, V/m)** 125% MT (E, V/m)**
Voluntary TMS
1246 38 37 70 87
1265 26 28 77 96
1280 37 40 59 73
1281 27 24 100 125
1286 31 33 54 66
1316 22 22 109 137
1355 29 34 59 73
Mean 29.9 31.2 79.2 94.1
*

Depth (in mm) from scalp surface to center‐of‐mass of M1 activation induced by movement of the right index finger (voluntary) and by transcranial magnetic stimulation (TMS) eliciting movement of the right first dossal interosseous muscle (FDI). The two distances did not differ significantly but did covary significantly (r = 0.93; Fig. 4).

**

Absolute E field values at the response site for stimulation at motor threshold and at 125% of motor threshold (MT) were computed in volts per meter (V/m) using a 3D computer model of the E field created by the Cadwell coil scaled by the machine setting (% output) and the distance from the scalp.