Skip to main content
. 2004 Mar 5;22(1):1–14. doi: 10.1002/hbm.20006

Table IV.

TMS stimulation intensity

Group % Output E at scalp (V/m) M1 depth (mm) E at M1 (V/m)*
PET Responders
 1246 80 348 38 87
 1265 66 284 26 96
 1280 75 325 37 73
 1281 72 312 27 125
 1286 55 235 31 66
 1316 72 312 22 137
 1355 62 267* 29 73
 Mean 68.9 297.8 29.9 94.1
Non‐responders
 1266 62 270 29 87
 1285 75 326 21 120
 1328 72 269 32 91
 1329 70 304 44 87
 Mean 67.3 292.5 27.3 96.1

There was no difference in intensity of the applied E field between subjects in whom a cortical response to TMS was observed with PET (n = 7) and those in whom a cortical response to transcranial magnetic stimulation (TMS) was not observed with PET (n = 4). % Output, percentage of maximum output of the coil. E, E fields; M1 depth, depth of M1 response to voluntary finger movement from the scalp surface.

*

E at M1 is the absolute E field at the depth of M1.