Skip to main content
. 2019 Nov 19;5(11):e02804. doi: 10.1016/j.heliyon.2019.e02804

Table 2.

Fe–6Si AC core loss in Watts/kg. measured at a fixed frequency of 60 Hz at various applied fields. The dimensions of the stator ring: OD = 33.32 mm, ID = 21.77 mm and thickness = 1.02 mm”. Density = 7.31 g/cm3.

Bm (T) Corr loss of as-printed and sintered Corr loss of sintered and further post-annealed in H2 at 750 °C, 2 h Corr loss of sintered and further post-annealed in H2 at 800 °C, 2 h
0.5 2.77 1.96 1.87
1 14.99 14.23 13.99
1.5 39.37 41.64 41.34