Skip to main content
. Author manuscript; available in PMC: 2019 Nov 26.
Published in final edited form as: Cancer. 2017 Jan 24;123(9):1516–1527. doi: 10.1002/cncr.30518

Table 1:

Screening test characteristics used in the analysis.

Test Characteristic Value (Range) Varied in Sensitivity Analysis Source
Test Characteristic
Sensitivity of FOBT 0.643 (0.356, 0.86) No 14, 15
Sensitivity of FIT 0.818 (0.478, 0.968) No 14, 15
Sensitivity of Colonoscopy 0.95 (0.92, 0.99) No 1517
Sensitivity of Diagnostic Colonoscopy 0.95 (0.92, 0.99) No 15, 16
Sensitivity of Flex Sig 0.75 (0.72, 0.85) No 15, 18
Sensitivity of DNA 0.923 (0.83, 0.975) No 15, 19, 20
Sensitivity of CT Colonography 0.922 (0.84, .93) No 15, 21, 22
Sensitivity of Test X (Set to match DNA) 0.923 (0.83, 0.975) No
Sensitivity of DNA Testing for Adenoma 0.424 (0.389–0.46) No 15, 19, 20
Sensitivity of CT Colonography for Adenoma 0.8 (0.045–1) No 15, 22
Sensitivity of Test X for Adenoma (relative to colonoscopy) 0.5 (0.5–1) No
Specificity of FOBT 0.901 (0.893, 0.908) No 14, 15
Specificity of FIT 0.969 (0.964, 0.974) No 14, 15
Specificity of Colonoscopy 0.9 (0.9, 1) No 15, 16
Specificity of Diagnostic Colonoscopy 0.9 (0.9, 1) No 15, 16
Specificity of Flex Sig 0.92 (0.92, 1) No 15, 16, 18, 23
Specificity of DNA 0.866 (0.859, 0.872) No 15, 19, 20
Specificity of CT Colonography 0.82 (0.796, 0.88) No 15, 21, 22
Specificity of Test X (Set to match DNA) 0.866 (0.859, 0.872) No
Test Compliance
Compliance Referent 1
Compliance with FOBT 0.462 (0.462, 1) Yes 24
Compliance with FIT- extrapolated using FOBT 0.462 (0.462, 1) Yes 24
Compliance with FOBT + Flex Sig- extrapolated using Flex Sig 0.63 (0.63, 1) Yes 25
Compliance with FIT + Flex Sig- extrapolated using Flex Sig 0.63 (0.63, 1) Yes 25
Compliance with Colonoscopy- extrapolated using Flex Sig 0.63 (0.63, 1) Yes 25, 26
Compliance with Flex Sig 0.63 (0.63, 1) Yes 25
Compliance with FOBT 2 0.597 (0.597, 1) Yes 24, 27
Compliance with FIT 2 0.597 (0.597, 1) Yes 24, 27
Compliance with FOBT 2 + Flex Sig 0.63 (0.63, 1) Yes 25
Compliance with FIT 2 + Flex Sig 0.63 (0.63, 1) Yes 25
Compliance with DNA 1- extrapolated using FOBT 0.462 (0.462, 1) Yes 24
Compliance with DNA 3- extrapolated using FOBT 2 0.597 (0.597, 1) Yes 24, 27
Compliance with Test X - extrapolated using FOBT 0.462 (0.462, 1) Yes 24
Compliance with Test X 3 - extrapolated using FOBT 2 0.597 (0.597, 1) Yes 24, 27
Compliance with Test X 5- extrapolated using Flex Sig 0.63 (0.63, 1) Yes 25
Compliance with CT Colonography- extrapolated using Flex Sig 0.63 (0.63, 1) Yes 25