Skip to main content
. 2019 Nov 20;7:782. doi: 10.3389/fchem.2019.00782

Table 2.

RMSE calculated using multiple settings for all baseline methods.

Dataset Setting Method/reference of results
KronRLS SimBoost DeepDTA PADME-EFP PADME-GC WideDTA
Davis
(Kd)
s1 0.608***
0.61562**
0.57294*
0.247
0.53103**
0.48197*
0.5109 0.43219 0.43225 0.5119
s2 0.84048* N/A N/A 0.78535 0.80644 N/A
s3 0.65964* N/A N/A 0.56005 0.57840 N/A
Metz
(Ki)
s1 0.562***0.78128* 0.1660
0.58154*
N/A 0.55293 0.59926 N/A
s2 0.78429* N/A N/A 0.71170 0.74292 N/A
s3 0.89889* N/A N/A 0.79154 0.81893 N/A
KIBA s1 0.620*** 0.64109** 0.65664* 0.204 0.47117**
0.46888*
0.4405 0.43214 0.418691 0.42308
s2 0.70243* N/A N/A 0.60201 0.62029 N/A
s3 0.68111* N/A N/A 0.61677 0.62345 N/A
ToxCast s1 N/A N/A N/A 0.40563 0.40779 N/A
s2 N/A N/A N/A 0.4485 0.44502 N/A
s3 N/A N/A N/A 0.48698 0.49439 N/A

The star symbols denote results that are not self-reported, i.e., the single star

*

indicates that PADME reported the other methods results, double stars

**

indicates that DeepDTA reported the other methods results, and the triple stars

***

indicates that SimBoost reported the other methods results. Missing data are indicated with N/A. The best values for each setting are indicated in bold font.