Skip to main content
. 2019 Nov 27;14(11):e0225648. doi: 10.1371/journal.pone.0225648

Table 2. Final pullout strength, number of completed cycles at system failure and absolute numbers of anchor pullout as failure mechanism.

Final pullout strength (N) Completed number of cycles at pullout Anchor pullout
Mean conventional anchor (n = 14) 259 ± 61 4093 ± 1142 13/14
Mean all-suture anchor (n = 14) 247 ± 78 3791 ± 1349 14/14
p-value 0.65 0.52