Abstract
Optical coherence tomography (OCT) is increasingly used to obtain objective measurements of the retinal nerve fiber layer (RNFL), optic nerve head and macula for assessing glaucoma progression. Although OCT has been widely adopted in clinical practice, uncertainty remains concerning how it should be best utilized. Questions include: What is the best structure to measure? What quantity of change is significant? Are structural changes relevant to the patient? How are longitudinal measurements affected by aging, and how can changes due to aging be differentiated from true progression? How should OCT be used alongside visual fields, and how often should OCT be performed? Recent studies have addressed some of these questions.
Important developments include appreciation of the need to use a consistent point of reference for structural measurements, leading to the introduction of Bruch’s membrane opening (BMO)–based measures including BMO-minimum rim width and BMO-minimum rim area. Commercially available OCT devices also permit analysis of macular changes over time, for example, changes in the ganglion cell and inner plexiform layers, the sites of the retinal ganglion cell bodies and dendrites, respectively. Several longitudinal studies have compared rates of change in RNFL and macular measurements, with some suggesting the relative value of each parameter may differ at different stages of disease. In early disease, looking for change over time may also be useful for glaucoma diagnosis, with advantages over classifying eyes using cross-sectional normative databases.
Optimal glaucoma management requires information from imaging and visual fields and efforts have been made to combine information, reducing the noise inherent in both tests to benefit from their different performances according to the stage of the disease. Combining information from different structural measurement may also be useful. There is now substantial evidence that progressive structural changes are of direct clinical relevance, with progressive changes on OCT often preceding functional loss and patients with faster change on OCT at increased risk of worsening visual losses. Identification of such patients offers the possibility of commencing or escalating treatment at an earlier stage. This review appraises recent developments in the use of OCT for assessing glaucoma progression.
PRECIS
This review addresses critical questions related to the use of optical coherence tomography for assessing glaucoma progression with retinal nerve fiber layer, macular and optic nerve head measurements.
Detecting and assessing rates of progression is an indispensable constituent of glaucoma management as it provides a means to identify rapidly progressing patients who are at high risk of visual disability, and who may require escalation in treatment. Progression is conventionally measured by observing for changes in visual field sensitivity, however many patients have changes to the optic disc or retinal nerve fiber layer (RNFL) in the absence of deterioration on automated perimetry, providing an opportunity to commence or increase treatment before significant decline in vision.1,2 Detecting structural change over time is also useful for diagnosing glaucoma, with advantages over classifying an eye as normal, abnormal or borderline by comparing a single scan to a normative database. Normative databases have strict inclusion criteria, consist largely of patients of European ancestry, and exclude those with high refractive error, or ocular co-morbidities. Normal structural measurements vary widely between individuals increasing the chances of misclassification. In some cases, due to the wide-range of normal, significant neural losses may occur before a patient is deemed to be “outside normal limits”. Establishing baseline structural measurements and observing for change over time has great value as an aid to diagnosis, particularly in glaucoma suspects.
Detection of glaucomatous structural changes has traditionally relied on assessment of optic disc photographs, however, agreement among glaucoma specialists in judging change on disc photographs is only “slight to fair’ and photographs do not allow quantification of rates of change.3 Optical coherence tomography (OCT) overcomes some of the limitations of optic disc photography and can be used to provide objective measurements of the retinal nerve fiber layer (RNFL), optic nerve head (ONH) and macula, useful for glaucoma diagnosis and progression analysis. Although OCT has been widely adopted in glaucoma clinics, uncertainty remains concerning how OCT should be best used to detect glaucoma progression. Pertinent, and only partially answered questions, include: What is the best structure to measure? What quantity of change is significant? Are structural changes relevant to the patient? How are longitudinal measurements affected by aging, and how can changes due to aging be differentiated from true progression? How should OCT be best used alongside visual fields and how often should OCT be performed?
What is the best structure to measure?
The ideal parameter for measuring glaucoma progression should be highly reproducible and useful at all stages of disease. OCT measurements of rates of change in glaucoma have focused largely on circumpapillary RNFL (cpRNFL) thickness, which is also the most widely used parameter in clinical practice. Recent studies have however indicated that additional information can be gleaned from examining changes in RNFL in other regions, for example, by examining the topography of RNFL loss across a 6 × 6 mm2 optic disc cube scan RNFL map.4 OCT devices now also provide the ability to quantify changes to the glaucomatous macula using measurements such as ganglion cell inner plexiform layer (GCIPL) and ganglion cell complex (GCC) thickness, which includes the ganglion cell layer, inner plexiform layer, and RNFL; the sites of retinal ganglion cell bodies, dendrites and axons respectively. Macular measures are of special interest due to the density of retinal ganglion cells located in this region and the realization that, contrary to conventional teaching, the macula is often involved early in the glaucomatous process.5,6 Some OCT devices now also include the ability to obtain novel optic nerve head metrics such as Bruch’s membrane opening-minimum rim width and Bruch’s membrane opening -minimum rim area (BMO-MRW, BMO-MRA).7–9, which use Bruch’s membrane opening (BMO) as an anatomical point of reference landmark for measurements and are discussed in more detail below.
The first report of OCT to examine glaucoma progression used a prototype time domain OCT (TDOCT) device to measure changes in RNFL thickness over time.10 The device was limited by poor reproducibility, which may have resulted in false positive assumptions of progression, however the study demonstrated the potential of OCT for detecting longitudinal change. Using a commercially available TDOCT device (Stratus OCT, Carl Zeiss Meditec Inc, Dublin, CA), Medeiros and colleagues compared the ability of cpRNFL, ONH and macular measurements to differentiate eyes progressing on standard automated perimetry (SAP) and optic disc stereophotographs from those that remained stable using conventional tests.11 cpRNFL performed significantly better than ONH and macular parameters at discriminating progressing and stable eyes, with faster rates of cpRNFL thinning observed in progressing eyes (−0.72 vs. 0.14 μm/year; P = 0.004).
TDOCT has now been superseded by spectral domain OCT (SDOCT), which has improved scan speed and higher resolution, and incorporates innovations such as real-time eye-tracking to compensate for eye movements during data acquisition and reduce motion artifacts. TDOCT was limited by inability to register images on follow up scans, meaning measurements from disparate retinal locations could be included in analyses of change over time. In contrast, SDOCT devices can automatically center follow-up scans on previously scanned locations by identifying retinal landmarks, which results in improved reproducibility and better ability to detect progression compared to TDOCT.12,13
Several studies have used SDOCT to evaluate the role of cpRNFL and macular measurements for assessing glaucoma progression (Table 1).14–23 It is however difficult to determine whether one parameter is better than another due to the lack of a gold standard and, although all glaucomatous changes reflect loss of retinal ganglion cells, there is still poor understanding of the temporal relationship between changes to the ONH, RNFL and macula. Studies have either compared rates of structural change occurring in glaucomatous eyes to rates in healthy subjects17,18,20,,22–25, or have examined the association between rates of change on OCT and contemporaneous or future changes on conventional structural or functional assessments.14,16,19,26–28 Overall, both cpRNFL and macular measures show faster rates of loss in glaucomatous eyes compared to controls, however, there is wide variation in reported rates of change. This is to be expected though as trend-based analyses of visual field sensitivities have also demonstrated disparate slopes among different individuals.29 It is also inappropriate to directly compare rates of change between studies and between parameters due to different baseline thicknesses and dynamic ranges. One approach that helps overcome this problem is to examine rates of change with values normalized for dynamic range. Using this approach to study 97 glaucomatous eyes followed for an average of 3.2 years, Hammel et al. found normalized cpRNFL thickness to decrease by 1.7% per year compared only a 1.3% per year decrease in mGCIPL thickness.23 This 1.3 fold faster rate of cpRNFL loss suggests that cpRNFL may be a more sensitive index of progression, however, among eyes with advanced glaucoma, where no further change in cpRNFL was observed, there was significant downward slope in mGCIPL thickness. Therefore, the relative value of cpRNFL and mGCIPL measurements may vary at different stages of disease, with macular measurements possibly of value for monitoring eyes with advanced glaucoma, beyond the floor observed in cpRNFL measurements.30 These findings were also supported by Sung et al. who found eyes with advanced glaucoma with visual field progression had significantly faster rates of macular thickness loss compared to non-progressing eyes, whereas there was no significant difference in rate of cpRNFL change between groups.16 It is however important to exercise caution in interpreting the results of these studies as the rate of change is not the only variable of importance in determining which parameter could be of most value for detecting progression. For example, a faster rate of change in cpRNFL compared to mGCIPL may be offset by differences in reproducibility of cpRNFL and mGCIPL measurements.
Table 1.
Summary of studies using SDOCT to examine longitudinal structural changes in glaucomatous and healthy eyes.
| Study | Subjects | Number of eyes | Average Baseline MD (dB) | Follow-up (years) | Parameters | Device | Mean rate of change (μm/year) | Comments |
|---|---|---|---|---|---|---|---|---|
| Leung 201123 | Glaucoma | 128 | −9.43 | 2 to 2.75 | cpRNFL | Cirrus | Ranged from −1.52 to −5.03 | SDOCT outperformed TDOCT |
| Stratus | Ranged from −2.22 to −7.60 | |||||||
| Leung 201224 | Healthy | 35 | N/A | 2.5 | cpRNFL | Cirrus | −0.52 ± 0.34 | Mean rates of change of superior and inferior cpRNFL were −1.35 ± 0.7 and −1.25 ± 0.5 μm/year. |
| Na 201213 | Preperimetric Glaucoma | 103 | −3.50 | 2.13 | mGCIPL | Cirrus | Not reported. | 38 of 114 eyes (27%) showed progression by optic disc photographs or VF during follow up. There was poor agreement between loss of mGCIPL or cpRNFL and progression using conventional measures. |
| cpRNFL | ||||||||
| Perimetric Glaucoma | 38 | −0.28 | mGCIPL | Progression was defined as significant negative slope in OCT measures over time. | ||||
| cpRNFL | ||||||||
| Healthy | 61 | 0.17 | ||||||
| Na 201314 | Progressing glaucoma | 63 | −4.3 | 2.2 | cpRNFL | Cirrus | −1.26 | Progressing glaucoma was defined by the presence of changes on optic disc photographs ± VF progression analysis. |
| Rim area | −0.016 mm2/year | |||||||
| Macular thickness | −1.82 | |||||||
| Non-progressing glaucoma | 216 | −0.8 | cpRNFL | −0.94 | ||||
| Rim area | −0.006 mm2/year | |||||||
| Macular thickness | −1.51 | |||||||
| Sung 201215 | Advanced Glaucoma | 98 | −14.3 | 2.2 | Macular thickness | Cirrus | −2.43 ± 4.28 | Eyes progressing on VF had faster rates of macular thickness loss than eyes not progressing on VF (−4.74 ± 4.40 versus −0.53 +/− 1.44 μm/ year). Rates of cpRNFL loss were similar between groups. |
| cpRNFL | −0.98 ± 2.45 | |||||||
| Leung 201316 | Glaucoma | 150 | Not reported* | 3.8 | cpRNFL | Cirrus | −1.53 | Age-related change in mGCIPL but not cpRNFL was related to baseline thickness measurements. |
| mGCIPL | −0.81 | |||||||
| Healthy | 72 | cpRNFL | −0.057 | *Average baseline cpRNFL and mGCC thicknesses were 70.6 μm and 98.1 μm in glaucomatous eyes. | ||||
| mGCIPL | −0.32 | |||||||
| Wessel 201325 | Progressing glaucoma | 13 | −2.8 | 3 | cpRNFL | Spectralis | −2.12 | Patients progressing on optic disc photographs had significantly faster rates of cpRNFL loss compared to those not progressing and healthy subjects. |
| Non-progressing glaucoma | 25 | −4.6 | −1.18 | |||||
| Healthy | 24 | −0.2 | −0.60 | |||||
| Iverson 201417 | Glaucoma suspects and Preperimetric Glaucoma | 74 | −0.3 | 3.6 | cpRNFL | RTVue | −1.15 | Approximately half of cpRNFL and mGCC measurements classified as outside normal limits were not replicated on subsequent scans. |
| mGCC | −0.52 | |||||||
| Healthy | 23 | −0.4 | 3.7 | cpRNFL | −0.91 | |||
| mGCC | −0.75 | |||||||
| Naghizadeh 201418 | Glaucoma | 51 | −10.2 | 2.0 | cpRNFL | RTVue | −0.33 | 10 of 51 glaucoma patients had VF progression during follow up. mGCC but not cpRNFL loss was significantly faster in glaucomatous eyes with VF progression compared to glaucomatous eyes with stable VFs. |
| mGCC | −0.20 | |||||||
| Healthy | 17 | −0.9 | cpRNFL | −0.24 | ||||
| mGCC | −0.02 | |||||||
| Miki 201427 | Glaucoma suspects developing VF defect | 40 | −0.8 | 2.2 | cpRNFL | Spectralis | −2.02 | The rate of cpRNFL loss was more than twice as fast in eyes that developed a VF defect during follow up compared to those that did not. |
| Glaucoma Suspects not developing VF defect | 414 | −0.3 | −0.82 | |||||
| Na 201519 | Preperimetric Glaucoma | 87 | −0.88 | 2.5 | cpRNFL | Cirrus | −0.62 | Eyes with perimetric glaucoma had significantly faster rates of change in the fovea and inferior macular than eyes with preperimetric glaucoma but there was no significant difference in rates of change in cpRNFL thickness |
| Macular thickness | −1.56 | |||||||
| 40 | −3.98 | cpRNFL | −0.69 | |||||
| Perimetric Glaucoma | Macular thickness | −1.18 | ||||||
| Gardiner 201520 | Glaucoma and OHT | 157 | −1.2 (most recent) | MRW | Spectralis | −1.6 (95% range −9.4 to 3.3) | cpRNFL had a better longitudinal signal to noise ratio (−0.58y−1) than MRW (−0.44y−1) or MRA (−0.23y−1) meaning true change may be easier to differentiate from noise using cpRNFL. | |
| MRA | ||||||||
| cpRNFL | −0.005mm2/year (95% range −0.035 to 0.020) | |||||||
| −1.0 (−3.2 to 1.0) | ||||||||
| Holló 201621 | Healthy | 34 | −1.1 | 5.3 | cpRNFL | RTVue | −0.33 ± 0.51 | cpRNFL loss of > −1.5 μm/year or mGCC loss > −1.3 μm/year were deemed strongly suggestive of uncontrolled glaucomatous progression. |
| mGCC | −0.53 ± 0.36 | |||||||
| OHT | 34 | 0.1 | cpRNFL | −0.44± 0.62 | ||||
| mGCC | −0.54 ± 0.52 | |||||||
| Glaucoma | 122 | −10.1 | cpRNFL | −0.69 ± 0.93 | ||||
| mGCC | −0.80 ± 0.78 | |||||||
| Zhang 201647 | Healthy | 192 | N/A | 2.5 | mGCC | RTVue | −0.25 ± 0.05 | Age-related rates of thinning in mGCC and cpRNFL were approximately 0.2% per year. There was no significant effect of IOP on rates of age-related loss in healthy subjects. |
| cpRNFL | −0.14 ± 0.07 | |||||||
| Yu 201626 | Glaucoma | 240 | −9.5 | 5.8 | cpRNFL | Cirrus | Eyes with and without cpRNFL thinning on GPA had −0.76%/year and −0.26%/year deterioration in VFI respectively (P=0.019) | Progressive RNFL thinning on trend-based progression analysis was strongly predictive of subsequent VF loss, with a 9-fold increased risk of VF progression using EMGT criteria for eyes progressing on RNFL GPA. |
| Hammel 201722 | Healthy | 28 | −0.1 | 1.7 | cpRNFL | Cirrus | N/A | Normalized rates of progression were faster for cpRNFL than mGCIPL. Progressive loss of mGCIPL but not cpRNFL was detectable in eyes with advanced glaucoma. |
| mGCIPL | N/A | |||||||
| Glaucoma | 97 | −4.3 | 3.2 | cpRNFL | −0.98 ± 0.22 (−1.7 ± 0.4%/year) | |||
| mGCIPL | −0.57 ± 0.16 (−1.3 ± 0.4%/year) | |||||||
Abbreviations: GS = Glaucoma Suspect, OHT = Ocular hypertension, cpRNFL = circumpapillary retinal nerve fiber layer thickness, mGCC = macular ganglion cell complex, mGCIPL = macular ganglion cell inner plexiform layer, VF= visual field, EMGT = Early Manifest Glaucoma Trial. GPA =Guided Progression Analysis.
With an increasing number of OCT parameters available to monitor glaucoma progression, there may be confusion as to which parameter to use. To date, evidence suggests that measures of RNFL, ONH and macular are complimentary and that using multiple parameters will increase sensitivity for detecting change. On the other hand, the use of multiple parameters may increase the number of eyes falsely labelled as progressing. The availability of multiple structural parameters therefore presents an opportunity and a challenge, which may be best addressed by combining results into a single metric. For example, Mwanza and colleagues found an index that combined information from macula and ONH OCT scans was better able to differentiate healthy eyes from those with early glaucoma compared to individual measures.31
What quantity of change is significant?
It is important to quantify the reproducibility of measurements as timely detection of progression depends on the ability to differentiate true change from the noise of test-retest variability. Several studies have shown SDOCT cpRNFL measurements have excellent short term reproducibility.32–35 Using Cirrus OCT (Zeiss Meditec, Dublin, CA), Mwanza et al. reported average cpRNFL thickness to have an intervisit intraclass correlation coefficient (ICC) of 97.2%.34 Macular measurements also had excellent reproducibility, with mGCIPL thickness using Cirrus OCT achieving an intervisit ICC of 98.0%, with a test-retest standard deviation of only 1.16 μm.35 It was suggested that a short term change in average cpRNFL thickness of 4 μm may be considered as suspicious of glaucoma progression, which was similar to the change of 5 μm suggested by Leung et al.32 It is however important to exercise some caution when interpreting such cut-offs and confidence of detecting true change can be increased by having two or more baseline measurements and confirming change on subsequent scans. Due to lower reproducibility of sectorial compared to average cpRNFL thickness, relatively greater change would be needed in sectors for similar confidence of true change (approximately 7 μm for temporal, superior and inferior quadrants, and 8 μm for the nasal quadrant).34 Considering that the current dynamic range of OCT RNFL thickness measurements ranges from a maximum of approximately 80 to 100 μm in healthy subjects to a floor of approximately 50 μm, an intervisit variability of 5 μm, represents more than 10% of the dynamic range, which could considerably reduce the value of OCT for detecting change if relying on such guidelines.
It is also important to acknowledge that most studies examining reproducibility excluded poor quality scans and examined short, rather than long term reproducibility, which may further increase variability. Nevertheless, a study examining 6-month reproducibility in stable glaucoma patients still reported good reproducibility with ICCs for average cpRNFL and mGCIPL thickness of 0.97 and 0.99 respectively, with reproducibility not influenced by glaucoma severity.36 A tolerance limit of 4 μm change in mGCIPL thickness was suggested as a likely indictor of progression. Also, OCT cpRNFL measurements have been shown to have lower longitudinal signal to noise ratios than standard automated perimetry, which is an important factor in identifying true change.37
OCT technology is also rapidly evolving and there are likely to be future improvements in measurement reproducibility, and possibly enhanced dynamic range, which may improve ability to detect change. For example, de-centration of the cpRNFL scan is a common artefact, reported over one in four SDOCT scans.38,39,40 De-centration of the circle scan by just 0.1mm can result in a 2.3 ± 2.0 μm error in average RNFL thickness, with sectorial measures even more vulnerable to displacement error as the RNFL is thinner further from the optic nerve head.39 Previously, cpRNFL circle scans were centered manually on the optic disc, however, subjective location of the disc margin has been found to correspond poorly to a defined structure on OCT.6 In contrast, an alternative landmark, the BMO, can be identified automatically on radial OCT scans of the optic nerve head, the orientation of the scan can be adjusted according to the BMO-fovea axis to account for difference in cyclotorsion, and the cpRNFL scan centered on the BMO (RNFL-BMO). A recent study has shown that although overall RNFL-BMO measurements have similar ability to detect glaucoma compared to traditional RNFL measurements, RNFL-BMO performed better in eyes with larger width externally oblique border tissue, a feature of titled optic discs.41 There is however a lack of studies examining the long term reproducibly of RNFL-BMO and its ability to detect progression.
Other parameters can also be measured relative to the BMO, for example, the BMO-MRW (the minimum distance from BMO to the internal limiting membrane) and BMO-MRA, which overcomes the inverse relationship between disc size and BMO-MRW.9,42 It has been shown that the BMO-MRW can be used to accurately differentiate glaucomatous and healthy eyes, in one study performing better than cpRNFL thickness.7,8 One might suppose that measurements taken relative to BMO, would perform better than conventional structural measures at detecting glaucoma progression, given the relatively stability of the BMO as a point of reference for repeat scans. However, a recent study by Gardiner et al. has suggested that BMO-MRW and BMO-MRA may be less able to detect change due to a relatively low longitudinal signal to noise ratio compared to cpRNFL.21 This observation may have been due to changes in the location of the BMO over time, possibly related to fluctuations in IOP or due to connective tissue remodeling with glaucoma progression. Recently, based on a cross-sectional analysis, Johnstone et al. reported that the BMO is located more posteriorly in older compared to younger individuals, suggesting that it might migrate posteriorly with age and be a less stable landmark than hoped.43 However, in contrast, a longitudinal study following 95 eyes for a period of 3 to 4 years found the location of the BMO to be stable over time.44 Longer duration studies are needed to confirm to determine whether the BMO can be used as a long-term stable reference from which to measure glaucomatous changes and to evaluate the potential benefits of orientating scans using the fovea-BMO axis.
Are structural changes relevant to the patient?
Regardless of which parameter might be best, there is now a large body of evidence that progressive changes on OCT are clinically relevant. Several studies have shown good agreement between progressive cpRNFL loss on OCT and changes on optic disc photographs.11,26 For example, Wessel et al. found eyes with progressive changes on optic disc photographs had significantly faster rates of cpRNFL loss than glaucomatous eyes not progressing on photographs,26 with others reporting a similar faster rate of change in macular measurements.19 Faster rates of cpRNFL loss on OCT are also associated with higher risk of future development of visual field defects. In a study of 554 eyes suspected of having glaucoma at baseline but with normal visual fields, Miki et al. found faster rates of cpRNFL loss were strongly associated with subsequent development of a visual field defect.28 Each 1 μm/year faster rate of cpRNFL loss corresponded to a 2.05 times higher risk of developing a VF defect. Yu et al found similar results in eyes with established glaucoma, with progressive RNFL thinning on trend-based progression analysis strongly predictive of VF loss.27 Displacement of the lamina cribrosa relative to the BMO may also be a useful marker of progression, with a report of a higher risk of visual field progression in eyes with faster increasing posterior displacement of the anterior lamina cribrosa and ONH surface.45 Faster rates of cpRNFL loss are also associated with faster decline in quality of life and worse performance on driving simulation, with information from OCT offering additional predictive value compared to information from visual field testing alone.46,47 OCT progression analysis therefore offers the possibility to detect patients at high risk of worsening visual function, and provide an objective means of quantifying glaucomatous neural losses directly related to quality of life.
How are measurements affected by aging?
Glaucoma progression must be differentiated from normal age-related changes to cpRNFL and macula.17,25,48,49 Leung et al. found mean rates of change in average, superior, and inferior cpRNFL thickness of −0.52 (95% CI −0.86 to −0.17), −1.35 (95% CI, −2.05 to −0.65) and −1.25 (95% CI, −1.78 to −0.7) μm per year, although the average follow up was only 30 months.25 Age-related average mGCIPL losses were −0.32 μm per year.17 In a subsequent study, which followed 90 patients (150 eyes) for an average of 46 months, 50% of glaucomatous eyes had progressive mGCIPL loss, however, when the lower 95% confidence interval for age-related changes was applied, the proportion progressing decreased to only 15%. In the future, it may be helpful to have longitudinal reference databases of healthy subjects to help determine whether an observed rate of change is pathological or an expected change for age.
It is important to note that high rates of false-positive detection of progression may occur when progression is considered to have occurred merely if a statistically significant negative slope of change is present (i.e., a slope that is statistically significantly different than zero with P<5%). For instance, with 5 years of annual testing, up to 25% of normal eyes can be falsely identified as having progressed if such criterion is employed for RNFL thickness change.50 A suggestion has been made that trend-based analysis of RNFL thickness change should at least involve testing the statistical significance of its change relative to the mean estimate of age-related changes.50 This would be analogous to evaluating visual field progression using mean deviation (MD) instead of mean sensitivity (with the former being an age-adjusted parameter), and could be described as an RNFL “mean deviation” trend analysis.
How should OCT be best used alongside visual fields?
Although OCT has a valuable role in assessing glaucoma progression, visual field testing remains the primary method of assessing glaucomatous damage and some patients develop visual field changes before detectable structural changes. The ability to detect progression by perimetry versus OCT is significantly influenced by the stage of disease, with eyes with less severe disease at baseline having a higher chance of being detected as progressing by OCT but not SAP and eyes with more advanced disease having a higher chance of being detected as progressing by SAP but not OCT.2 This phenomenon is due partly due to the different measurement scales of the devices, with SAP using a logarithmic scale that compresses results in early disease, reducing the ability to detect change, however differences in dynamic range also contribute.51 The result is that simultaneous detection of change in structural and functional measurements is rare 13,52 and it is therefore the consensus that both structural and functional tests should be monitored with equal diligence for optimal assessment of glaucoma progression.
This raises the question of how OCT should be best used to complement assessment of visual function. One approach is to use Bayesian probability theorem to allow information derived from OCT to influence inferences obtained from automated perimetry, and recent studies using this approach have shown progression slopes obtained from integrated measurements are better able to predict future visual field status than isolated information from either structural or functional domains.53,54 In another approach, OCT and perimetry data were combined into a single index after transforming the measurements to a common scale reflecting neural losses. The combined structure-function index has been shown to be able to improve detection, staging, prediction and assessment of progression compared to isolated measures from structure and function.55–57 Future research should concentrate on further developing these approaches to determine the most efficacious and cost-effective frequency of testing, and combination of tests, for detecting change at various stages of disease. Not only would these approaches potentially improve our ability to detect change, combining information from structural and functional tests, or from different structural measurements, provides an opportunity to simplify and simultaneously present results from an increasing range of tests.
In conclusion, since the introduction of OCT over 25 years ago, our ability to detect and quantify glaucomatous structural changes has been greatly enhanced. OCT provides a means to obtain reproducible measures of the RNFL, ONH and macula, each of which are of value in quantifying glaucoma progression. Although visual function is what matters most to patients, progressive structural changes can precede functional loss and patients with faster change on OCT are at increased risk of worsening visual losses, offering the possibility of escalating treatment at an earlier stage to better preserve vision. The ability to assess glaucoma progression is likely to be further improved by novel approaches to incorporate information from OCT and visual fields, reducing the noise inherent in both tests, and the next few years are likely to see such strategies included on commercial devices. There are however, important questions that still need to be addressed, particularly regarding testing strategies, to ensure the most effective use of OCT in clinical practice.
Acknowledgments
Financial Disclosure:
A.J.T. – Consultant for Allergan, Thea; F.A.M. – research support from Alcon Laboratories, Bausch & Lomb, Carl Zeiss Meditec, Heidelberg Engineering, Merck, Allergan, Sensimed, Topcon, Reichert, National Eye Institute; Consultant for Allergan, Carl Zeiss Meditec, Novartis.
Funding:
Supported by National Health Service Scotland Career Research Fellowship (A.J.T.), National Institutes of Health/National Eye Institute grants EY021818 (F.A.M.) and EY025056 (FAM)
References
- 1.Keltner JL, Johnson CA, Anderson DR, Levine RA, Fan J, Cello KE, Quigley HA, Budenz DL, Parrish RK, Kass MA, Gordon MO, and Ocular Hypertension Treatment Study Group. The association between glaucomatous visual fields and optic nerve head features in the Ocular Hypertension Treatment Study. Ophthalmology. 2006;113(9):1603–12. [DOI] [PubMed] [Google Scholar]
- 2.Abe RY, Diniz-Filho A, Zangwill LM, Gracitelli CP, Marvasti AH, Weinreb RN, Baig S, and Medeiros FA. The Relative Odds of Progressing by Structural and Functional Tests in Glaucoma. Invest Ophthalmol Vis Sci. 2016;57(9):421–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Jampel HD, Friedman D, Quigley H, Vitale S, Miller R, Knezevich F, and Ding Y. Agreement among glaucoma specialists in assessing progressive disc changes from photographs in open-angle glaucoma patients. Am J Ophthalmol. 2009;147(1):39–44. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Lin C, Mak H, Yu M, Leung, CKS. Trend-based progression analysis for examination of the topography of rates of retinal nerve fiber layer thinning in glaucoma. JAMA Ophthalmology. 2017;135(3):189–95. [DOI] [PubMed] [Google Scholar]
- 5.Curcio CA, and Allen KA. Topography of ganglion cells in human retina. Journal of Comparative Neurology. 1990;300(1):5–25. [DOI] [PubMed] [Google Scholar]
- 6.Hood DC, Raza AS, de Moraes CG, Liebmann JM, and Ritch R. Glaucomatous damage of the macula. Prog Retin Eye Res. 2013;32:1–21. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Reis AS, Sharpe GP, Yang H, Nicolela MT, Burgoyne CF, and Chauhan BC. Optic disc margin anatomy in patients with glaucoma and normal controls with spectral domain optical coherence tomography. Ophthalmology. 2012;119(4):738–47. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Chauhan BC, O’Leary N, Almobarak FA, Reis AS, Yang H, Sharpe GP, Hutchison DM, Nicolela MT, and Burgoyne CF. Enhanced Detection of Open-angle Glaucoma with an Anatomically Accurate Optical Coherence Tomography-Derived Neuroretinal Rim Parameter. Ophthalmology. 2013;120(3):535–43. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Gardiner SK, Ren R, Yang H, Fortune B, Burgoyne CF, and Demirel S. A method to estimate the amount of neuroretinal rim tissue in glaucoma: comparison with current methods for measuring rim area. Am J Ophthalmol. 2014;157(3):540–9.. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Wollstein G, Schuman JS, Price LL, Aydin A, Stark PC, Hertzmark E, Lai E, Ishikawa H, Mattox C, and Fujimoto JG. Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma. Archives of ophthalmology. 2005;123(4):464–70. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Medeiros FA, Zangwill LM, Alencar LM, Bowd C, Sample PA, Susanna R, and Weinreb RN. Detection of glaucoma progression with stratus OCT retinal nerve fiber layer, optic nerve head, and macular thickness measurements. Invest Ophthalmol Vis Sci. 2009;50(12):5741–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Langenegger SJ, Funk J, and Töteberg-Harms M. Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of Spectralis SD-OCT in glaucomatous and healthy control eyes. Invest Ophthalmol Vis Sci. 2011;52(6):3338–44. [DOI] [PubMed] [Google Scholar]
- 13.Leung CK, Cheung CY, Weinreb RN, Liu S, Ye C, Lai G, Liu N, Pang CP, Tse KK, and Lam DS. Evaluation of retinal nerve fiber layer progression in glaucoma: a comparison between the fast and the regular retinal nerve fiber layer scans. Ophthalmology. 2011;118(4):763–7. [DOI] [PubMed] [Google Scholar]
- 14.Na JH, Sung KR, Baek S, Kim YJ, Durbin MK, Lee HJ, Kim HK, and Sohn YH. Detection of glaucoma progression by assessment of segmented macular thickness data obtained using spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2012;53(7):3817–26. [DOI] [PubMed] [Google Scholar]
- 15.Na JH, Sung KR, Lee JR, Lee KS, Baek S, Kim HK, and Sohn YH. Detection of glaucomatous progression by spectral-domain optical coherence tomography. Ophthalmology. 2013;120(7):1388–95. [DOI] [PubMed] [Google Scholar]
- 16.Sung KR, Na JH, and Lee Y. Glaucoma diagnostic capabilities of optic nerve head parameters as determined by Cirrus HD optical coherence tomography. J Glaucoma. 2012;21(7):498–504. [DOI] [PubMed] [Google Scholar]
- 17.Leung CK, Ye C, Weinreb RN, Yu M, Lai G, and Lam DS. Impact of age-related change of retinal nerve fiber layer and macular thicknesses on evaluation of glaucoma progression. Ophthalmology. 2013;120(12):2485–92. [DOI] [PubMed] [Google Scholar]
- 18.Iverson SM, Feuer WJ, Shi W, Greenfield DS, and Group AIFGS. Frequency of abnormal retinal nerve fibre layer and ganglion cell layer SDOCT scans in healthy eyes and glaucoma suspects in a prospective longitudinal study. British Journal of Ophthalmology. 2014;98(7):920–5. [DOI] [PubMed] [Google Scholar]
- 19.Naghizadeh F, Garas A, Vargha P, and Holló G. Detection of early glaucomatous progression with different parameters of the RTVue optical coherence tomograph. J Glaucoma. 2014;23(4):195–8. [DOI] [PubMed] [Google Scholar]
- 20.Na JH, Sung KR, Baek SH, Kim ST, Shon K, and Jung JJ. Rates and patterns of macular and circumpapillary retinal nerve fiber layer thinning in preperimetric and perimetric glaucomatous eyes. J Glaucoma. 2015;24(4):278–85. [DOI] [PubMed] [Google Scholar]
- 21.Gardiner SK, Boey PY, Yang H, Fortune B, Burgoyne CF, and Demirel S. Structural Measurements for Monitoring Change in Glaucoma: Comparing Retinal Nerve Fiber Layer Thickness With Minimum Rim Width and Area. Invest Ophthalmol Vis Sci. 2015;56(11):6886–91. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Holló G, and Zhou Q. Evaluation of Retinal Nerve Fiber Layer Thickness and Ganglion Cell Complex Progression Rates in Healthy, Ocular Hypertensive, and Glaucoma Eyes With the Avanti RTVue-XR Optical Coherence Tomograph Based on 5-Year Follow-up. J Glaucoma. 2016;25(10):e905–e909. [DOI] [PubMed] [Google Scholar]
- 23.Hammel N, Belghith A, Weinreb RN, Medeiros FA, Mendoza N, and Zangwill LM. Comparing the Rates of Retinal Nerve Fiber Layer and Ganglion Cell-Inner Plexiform Layer Loss in Healthy Eyes and in Glaucoma Eyes. Am J Ophthalmol. 2017, in press. [DOI] [PubMed] [Google Scholar]
- 24.Leung CK, Chiu V, Weinreb RN, Liu S, Ye C, Yu M, Cheung CY, Lai G, and Lam DS. Evaluation of retinal nerve fiber layer progression in glaucoma: a comparison between spectral-domain and time-domain optical coherence tomography. Ophthalmology. 2011;118(8):1558–62. [DOI] [PubMed] [Google Scholar]
- 25.Leung CK, Yu M, Weinreb RN, Ye C, Liu S, Lai G, and Lam DS. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a prospective analysis of age-related loss. Ophthalmology. 2012;119(4):731–7. [DOI] [PubMed] [Google Scholar]
- 26.Wessel JM, Horn FK, Tornow RP, Schmid M, Mardin CY, Kruse FE, Juenemann AG, and Laemmer R. Longitudinal analysis of progression in glaucoma using spectral-domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2013;54(5):3613–20. [DOI] [PubMed] [Google Scholar]
- 27.Yu M, Lin C, Weinreb RN, Lai G, Chiu V, and Leung CK. Risk of Visual Field Progression in Glaucoma Patients with Progressive Retinal Nerve Fiber Layer Thinning: A 5-Year Prospective Study. Ophthalmology. 2016;123(6):1201–10. [DOI] [PubMed] [Google Scholar]
- 28.Miki A, Medeiros FA, Weinreb RN, Jain S, He F, Sharpsten L, Khachatryan N, Hammel N, Liebmann JM, Girkin CA, Sample PA, and Zangwill LM. Rates of retinal nerve fiber layer thinning in glaucoma suspect eyes. Ophthalmology. 2014;121(7):1350–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Chauhan BC, Malik R, Shuba LM, Rafuse PE, Nicolela MT, and Artes PH. Rates of glaucomatous visual field change in a large clinical population. Invest Ophthalmol Vis Sci. 2014;55(7):4135–43. [DOI] [PubMed] [Google Scholar]
- 30.Bowd C, Zangwill LM, Weinreb RN, Medeiros FA, and Belghith A. Estimating Optical Coherence Tomography Structural Measurement Floors to Improve Detection of Progression in Advanced Glaucoma. Am J Ophthalmol. 2017;175:37–44. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Mwanza JC, Warren JL, Budenz DL Combining Spectral Domain Optical Coherence Tomography Structural Parameters for the Diagnosis of Glaucoma With Early Visual Field Loss. Invest Ophthalmol Vis Sci. 2013;54(13):8393–400. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Leung CK, Cheung CY, Weinreb RN, Qiu Q, Liu S, Li H, Xu G, Fan N, Huang L, Pang CP, and Lam DS. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study. Ophthalmology. 2009;116(7):1257–63. [DOI] [PubMed] [Google Scholar]
- 33.González-García AO, Vizzeri G, Bowd C, Medeiros FA, Zangwill LM, and Weinreb RN. Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements. Am J Ophthalmol. 2009;147(6):1067–74. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Mwanza JC, Chang RT, Budenz DL, Durbin MK, Gendy MG, Shi W, and Feuer WJ. Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with cirrus HD-OCT in glaucomatous eyes. Invest Ophthalmol Vis Sci. 2010;51(11):5724–30. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Mwanza JC, Oakley JD, Budenz DL, Anderson DR, and Cirrus Optical Coherence Tomography Normative Database Study Group. Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes. Ophthalmology. 2011;118(2):241–8.e1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Kim KE, Yoo BW, Jeoung JW, and Park KH. Long-Term Reproducibility of Macular Ganglion Cell Analysis in Clinically Stable Glaucoma Patients. Invest Ophthalmol Vis Sci. 2015;56(8):4857–64. [DOI] [PubMed] [Google Scholar]
- 37.Gardiner SK, Fortune B, and Demirel S. Signal-to-Noise Ratios for Structural and Functional Tests in Glaucoma. Transl Vis Sci Technol. 2013;2(6):3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Liu Y, Simavli H, Que CJ, Rizzo JL, Tsikata E, Maurer R, and Chen TC. Patient characteristics associated with artifacts in Spectralis optical coherence tomography imaging of the retinal nerve fiber layer in glaucoma. American journal of ophthalmology. 2015;159(3):565–76. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Cheung CY, Yiu CK, Weinreb RN, Lin D, Li H, Yung AY, Pang CP, Lam DS, and Leung CK. Effects of scan circle displacement in optical coherence tomography retinal nerve fibre layer thickness measurement: a RNFL modelling study. Eye (Lond). 2009;23(6):1436–41. [DOI] [PubMed] [Google Scholar]
- 40.Vizzeri G, Bowd C, Medeiros FA, Weinreb RN, and Zangwill LM. Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph. J Glaucoma. 2008;17(5):341–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Lee EJ, Lee KM, Kim H, and Kim TW. Glaucoma Diagnostic Ability of the New Circumpapillary Retinal Nerve Fiber Layer Thickness Analysis Based on Bruch’s Membrane Opening. Invest Ophthalmol Vis Sci. 2016;57(10):4194–204. [DOI] [PubMed] [Google Scholar]
- 42.Enders P, Adler W, Schaub F, Hermann MM, Dietlein T, Cursiefen C, and Heindl LM. Novel Bruch’s Membrane Opening Minimum Rim Area Equalizes Disc Size Dependency and Offers High Diagnostic Power for Glaucoma. Invest Ophthalmol Vis Sci. 2016;57(15):6596–603. [DOI] [PubMed] [Google Scholar]
- 43.Johnstone J, Fazio M, Rojananuangnit K, Smith B, Clark M, Downs C, Owsley C, Girard MJ, Mari JM, and Girkin CA. Variation of the axial location of Bruch’s membrane opening with age, choroidal thickness, and race. Invest Ophthalmol Vis Sci. 2014;55(3):2004–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Belghith A, Bowd C, Medeiros FA, Hammel N, Yang Z, Weinreb RN, and Zangwill LM. Does the location of Bruch’s membrane opening change over time? Longitudinal analysis using San Diego Automated Layer Segmentation Algorithm (SALSA) stability of Bruch’s membrane opening location over time. Investigative ophthalmology & visual science. 2016;57(2):675–682. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Wu Z, Lin C, Crowther M, Mak H, Yu M, and Leung CK. Impact of Rates of Change of Lamina Cribrosa and Optic Nerve Head Surface Depths on Visual Field Progression in Glaucoma. Invest Ophthalmol Vis Sci. 2017;58(3):1825–33. [DOI] [PubMed] [Google Scholar]
- 46.Gracitelli CP, Abe RY, Tatham AJ, Rosen PN, Zangwill LM, Boer ER, Weinreb RN, and Medeiros FA. Association between progressive retinal nerve fiber layer loss and longitudinal change in quality of life in glaucoma. JAMA Ophthalmol. 2015;133(4):384–90. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Tatham AJ, Boer ER, Rosen PN, Della Penna M, Meira-Freitas D, Weinreb RN, Zangwill LM, and Medeiros FA. Glaucomatous retinal nerve fiber layer thickness loss is associated with slower reaction times under a divided attention task. Am J Ophthalmol. 2014;158(5):1008–17. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Sung KR, Wollstein G, Bilonick RA, Townsend KA, Ishikawa H, Kagemann L, Noecker RJ, Fujimoto JG, and Schuman JS. Effects of age on optical coherence tomography measurements of healthy retinal nerve fiber layer, macula, and optic nerve head. Ophthalmology. 2009;116(6):1119–24. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Zhang X, Francis BA, Dastiridou A, Chopra V, Tan O, Varma R, Greenfield DS, Schuman JS, Huang D, and Advanced Imaging for Glaucoma Study Group. Longitudinal and Cross-Sectional Analyses of Age Effects on Retinal Nerve Fiber Layer and Ganglion Cell Complex Thickness by Fourier-Domain OCT. Transl Vis Sci Technol. 2016;5(2):1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Wu Z, Saunders L, Zangwill LM, Daga F, Crowston JG, Medeiros FA. Impact of Normal Aging and Progression Definitions on Detection of Longitudinal Retinal Nerve Fiber Layer Thinning Using Optical Coherence Tomography. (in press). [DOI] [PubMed] [Google Scholar]
- 51.Medeiros FA, Zangwill LM, Bowd C, Mansouri K, and Weinreb RN. The structure and function relationship in glaucoma: implications for detection of progression and measurement of rates of change. Invest Ophthalmol Vis Sci. 2012;53(11):6939–46. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Medeiros FA, and Tatham AJ. Structure versus Function in Glaucoma: The Debate That Doesn’t Need to Be. Ophthalmology. 2016;123(6):1170–2. [DOI] [PubMed] [Google Scholar]
- 53.Medeiros FA, Leite MT, Zangwill LM, and Weinreb RN. Combining structural and functional measurements to improve detection of glaucoma progression using Bayesian hierarchical models. Invest Ophthalmol Vis Sci. 2011;52(8):5794–803. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Russell RA, Malik R, Chauhan BC, Crabb DP, and Garway-Heath DF. Improved estimates of visual field progression using bayesian linear regression to integrate structural information in patients with ocular hypertension. Invest Ophthalmol Vis Sci. 2012;53(6):2760–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Medeiros FA, Lisboa R, Weinreb RN, Girkin CA, Liebmann JM, Zangwill LM. A combined index of structure and function for staging glaucomatous damage. Arch Ophthalmol. 2012;130(9):1107–16. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Medeiros FA, Zangwill LM, Anderson DR, Liebmann JM, Girkin CA, Harwerth RS, Fredette MJ, Weinreb RN. Estimating the rate of retinal ganglion cell loss in glaucoma. Am J Ophthalmol. 2012;154(5):814–824. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.Meira-Freitas D, Lisboa R, Tatham A, Zangwill LM, Weinreb RN, Girkin CA, Liebmann JM, Medeiros FA. Predicting progression in glaucoma suspects with longitudinal estimates of retinal ganglion cell counts. Invest Ophthalmol Vis Sci. 2013;54(6):4174–83. [DOI] [PMC free article] [PubMed] [Google Scholar]