Skip to main content
. 2019 Mar 27;57(6):711–720. doi: 10.2486/indhealth.2018-0216

Table 3. Tested conditions during the criterion-related validity simulations.

Parameters
(Units)
Simulated scenario

1st 2nd 3rd 4th 5th
Acclimatization Yes No No No Yes
Posture Standing Standing Standing Standing Sitting
Duration 480 480 480 480 480
Ta (°C) 40 35 30 30 35
Tg (°C) 40 35 45 30 50
Va (ms-1) 0.30 0.10 0.10 1.00 1.00
RH (%) 35 60 35 45 30
M (W) 300 300 300 450 250
W (W) 0 0 0 0 0
Icl (clo) 0.5 0.5 0.8 0.5 1.0
Tr (°C) 40.0 35.0 52.0 30.0 74.6
Pa (kPa) 2.58 3.37 1.48 1.91 1.69
Ap (fraction %) 30 20
Fr (-) 0.15 0.15

The five hypothetical scenarios presented in Table 3 were obtained from ISO/DIS 7933:2018. As mentioned in Annex F of ISO/DIS 7933:2018, in all cases stationary or undefined walking conditions are assumed. Ta: air temperature; Tg: globe temperature; Va: air velocity; RH: relative humidity; M: metabolic rate; W: effective mechanical power; Icl: clothing insulation; Tr: mean radiant temperature; Pa: vapor pressure; Ap: fraction of the body surface area covered by reflective clothing; Fr: emissivity of the reflective clothing.