Meurice 1996.
Methods | Randomised, parallel group study. Statistical analysis based on t tests but unadjusted data presented for all outcomes. | |
Participants | N = 16 participants (16 M). Mean age: 54; BMI: 34.2 kg/m2; AHI: 43.6; ESS: 14.8 Inclusion criteria: diagnosis of OSA (confirmed by polysomnography; untreated OSA) Exclusion criteria: not reported |
|
Interventions | Auto‐CPAP versus fixed CPAP Study duration: 3 weeks |
|
Outcomes |
|
|
Funding & conflicts of interest statements | Not provided | |
Notes | ||
Risk of bias | ||
Bias | Authors' judgement | Support for judgement |
Random sequence generation (selection bias) | Low risk | Random numbers table |
Allocation concealment (selection bias) | Unclear risk | Information not available |
Blinding of participants and personnel (performance bias) Machine usage, symptoms, quality of life, withdrawal, adverse effects | Low risk | Participants unaware as to group they were randomised to (CPAP machines were identical). |
Blinding of participants and personnel (performance bias) AHI, blood pressure, treatment pressure | Low risk | These outcomes unlikely to be affected by awareness of treatment group. |
Blinding of outcome assessment (detection bias) Machine usage, symptoms, quality of life, withdrawal, adverse effects | Low risk | Participants unaware as to group they were randomised to (CPAP machines were identical). |
Blinding of outcome assessment (detection bias) AHI, blood pressure, treatment pressure | Low risk | These outcomes unlikely to be affected by awareness of treatment group. |
Incomplete outcome data (attrition bias) All outcomes | Low risk | All participants completed the study |
Selective reporting (reporting bias) | Unclear risk | Information not available |
Other bias | Low risk | No concerns identified |