Skip to main content
. 2019 Nov 8;19(22):4868. doi: 10.3390/s19224868

Table 1.

Fraction of areas with blisters and thickness greater than 4 µm for adhesive 1 layer. Not applicable (NA) values refer to samples that were scrapped before the pulse-echo test.

Serial Number Blisters Fraction (%) Area with Blisters (mm2) Thicker Adhesive 1 Bonding Line Fraction (%) Thicker Adhesive 1 Bonding Line Area (mm2) ΔResponse (Db)
15113 0.07 0.21 25.82 74.55 2.0
15114 0.04 0.11 33.14 97.05 NA
15115 0.90 2.60 53.81 157.46 3.2
15116 0.34 0.99 36.83 107.76 2.9
15117 0.16 0.48 37.66 110.19 3.8
15118 0.35 1.03 31.47 92.08 2.7
15119 0.28 0.83 41.06 120.30 2.7
15120 3.36 9.79 54.30 159.09 3.6
15121 0.17 0.51 37.28 109.27 2.4
15122 0.63 1.84 37.04 108.57 3.0
15123 3.95 10.94 88.32 258.86 4.5
15124 2.90 8.45 46.30 135.69 5.9
15125 0.82 2.34 44.25 127.77 2.7
15126 2.18 6.24 47.28 138.44 21.8
15127 0.86 2.47 40.09 115.68 2.5
15128 0.26 0.73 22.49 64.90 3.8
15129 0.90 2.57 65.51 189.04 3.1
15130 0.29 0.84 52.52 151.56 NA
15137 5.28 15.29 58.87 174.16 6.2
15138 6.21 17.98 63.72 188.51 6.9
15139 9.53 27.57 66.55 196.82 6.9
15140 4.87 14.10 60.05 177.59 7.3
15141 2.34 6.78 63.55 187.94 2.7
15142 4.31 12.47 63.26 187.10 4.8