Skip to main content
. 2019 Nov 9;24(22):4065. doi: 10.3390/molecules24224065

Table 1.

Method validation of the intraday precision and accuracy for the ten determinations of ginsenosides from standard samples.

Compound Nominal Concentration
(ng/mL)
Intraday
Observed Concentration
(ng/mL)
Precision
RSD (%)
Accuracy
Bias (%)
ginsenoside Rb1 25 25.93 ± 0.94 3.61 3.70
250 275.2 ± 3.80 1.38 10.06
500 500.7 ± 31.42 6.27 0.13
ginsenoside Rb2 25 23.79 ± 0.82 3.43 −4.86
250 278.8 ± 6.38 2.29 11.54
500 458.8 ± 29.00 6.32 −8.52
ginsenoside Rc 25 26.37 ± 0.61 2.33 5.49
250 250.5 ± 5.6 2.23 0.19
500 464.5 ± 31.02 6.68 −7.11
ginsenoside Rd 25 28.21 ± 0.82 2.90 12.5
250 266.9 ± 9.38 3.52 6.76
500 480.3 ± 23.44 4.88 −3.94
ginsenoside Re 25 28.22 ± 0.70 2.50 12.88
250 277.6 ± 9.19 3.31 11.06
500 533.2 ± 11.59 2.17 6.64
ginsenoside Rg1 25 22.78 ± 0.59 2.58 −8.86
250 259.1 ± 3.87 1.49 3.65
500 489.3 ± 15.77 3.22 −2.14

Data were expressed as the mean ± SD (n = 6).