Table 1.
Tendon | Max force (N) | Displacement at max force (mm) | Stiffness (N/mm) | Max stress (MPa) | Strain at max stress (mm/mm) | Elastic modulus (MPa) | Cross-sectional area (mm2) | Mechanical testing sample gauge length (mm) |
---|---|---|---|---|---|---|---|---|
P1 AT | 0.31±0.16 | 0.63±0.22 | 0.68±0.43 | 0.56±0.34 | 0.47±0.21 | 1.64±1.14 | 0.61±0.31 | 0.89±0.46 |
P5 AT | 0.91±0.27 | 0.92±0.34 | 1.66±0.78 | 1.04±0.030 | 0.50±0.18 | 2.64±1.02 | 0.66±0.62 | 1.55±0.29 |
P10 AT | 2.65±1.03 | 2.04±0.82 | 2.18±1.15 | 0.94±0.66 | 0.68±0.28 | 1.21±0.60 | 3.50±1.45 | 3.17±1.40 |
P5 TT | 0.30±0.18 | 1.59±0.74 | 0.26±0.16 | 1.15±0.55 | 0.61±0.29 | 2.66±1.57 | 0.27±0.12 | 2.89±1.23 |
P10 TT | 0.66±0.17 | 1.69±0.58 | 0.50±0.21 | 3.23±2.33 | 0.40±0.19 | 10.33±6.48 | 0.31±0.15 | 4.76±1.63 |