Skip to main content
. 2019 Oct 28;8(21):e012744. doi: 10.1161/JAHA.119.012744

Table 2.

Echocardiographic Measurements Early and Late From CRT in Patients With a Systemic LV

Variable Pre‐CRT (n=39) Early Follow‐Up (n=39) P Valuea Late Follow‐Up (n=25) P Valueb
LAVI, mL/m2 47.0 (33.0–58.0) 40.0 (30.0–55.0) 0.081 37.0 (22.0–54.5) 0.363
RAVI, mL/m2 39.0 (26.0–55.0) 32.0 (22.0–51.0) 0.010 34.0 (26.5–62.0) 0.486
LVEF, % 28.9±7.1 38.6±11.2 <0.001 35.6±12.7 0.014
LVEDD, mm 63.2±10.2 60.7±9.7 0.052 60.3±11.5 0.111
LVESD, mm 51.7±10.5 48.1±11.6 0.043 48.0±13.4 0.190
LVEDV, mL 216±76 185±66 0.010 193±82 0.055
LVESV, mL 155±65 118±57 0.001 124±68 0.010

Values are mean±SD or median (interquartile range). CRT indicates cardiac resynchronization therapy; LAVI, left atrial volume index; LV, left ventricle; LVEDD, LV end‐diastolic diameter; LVEDV, LV end‐diastolic volume; LVEF, LV ejection fraction; LVESD, LV end‐systolic diameter; LVESV, LV end‐systolic volume; RAVI, right atrial volume index.

a

Pre‐CRT vs early follow‐up.

b

Pre‐CRT vs late follow‐up.