Skip to main content
. 2018 Jun 5;14(6):797–802. doi: 10.1177/1558944718777831

Table 1.

Characteristics of the Specimens and Average Radiographic and Digital Measurements.

Sample Digit Age/sex of specimen Radiographic volar fragment size (%) Digitally measured volar fragment size (%) Average difference in measurement (%) P value for measurement—radiograph vs digital software P value for difference between exposure to prefractured image vs only fractured image
1 2 61 M 23.28 [10-45] 57.85 −34.575 <.0001 .978
2 3 61 M 32.95 [5-50] 30.35 2.6 .3281 .4328
3 4 61 M 32.33 [20-41] 36.95 −4.625 .0571 .169
4 2 55 M 33.20 [25-40] 37.70 −4.5 .1225 .9275
5 3 55 M 54.70 [15-65] 61.25 −6.55 .0526 .1529
6 4 55 M 10.30 [0-20] 20.90 −10.6 .004 .4106
7 2 57 F 14.20 [5-25] 30.40 −16.2 .0002 .4599
8 3 57 F 45.85 [30-60] 63.25 −17.4 <.0001 .6671
9 4 57 F 45.35 [15-55] 58.55 −13.2 .0095 .5634
10 2 51 M 75.60 [70-80] 80.90 −5.3 .0261 .7927
11 3 51 M 39.15 [25-50] 53.50 −14.35 .0006 .6021
12 4 51 M 26.23 [10-40] 43.25 −17.025 .0018 .7659
13 2 44 M 26.50 [15-40] 38.40 −11.9 .0004 .5673
14 3 44 M 27.88 [15-40] 26.50 1.375 .7345 .8423
15 4 44 M 38.65 [15-50] 46.40 −7.75 .0002 .931
16 2 51 M 63.13 [25-85] 65.90 −2.775 .8085 .6434
17 3 51 M 89.73 [70-100] 82.35 7.375 .2062 .5831
18 4 51 M 47.85 [35-66] 54.85 −7 .0951 .0456
Overall average difference in measurements Overall average P value for measurement—radiograph vs digital software
−9.02 .0008

Note. P values < .05 are indicated in bold.