Skip to main content
. Author manuscript; available in PMC: 2019 Dec 9.
Published in final edited form as: Hear Res. 2018 May 19;365:149–164. doi: 10.1016/j.heares.2018.05.014

Fig. 11:

Fig. 11:

Median and interquartile ranges for intracochlear pressure transfer function magnitudes for all specimens tested, shown for 7 and 28 kPa nominal peak pressure exposures. Responses are shown superimposed onto the range of responses observed to moderate sound pressure level tone pips (gray shading) reported previously (Greene et al., 2017; Nakajima et al., 2009).