Skip to main content
. 2019 Dec 9;9:17638. doi: 10.1038/s41598-019-53884-x

Table 2.

Macroscopic grading system adapted for implant osseointegration in proof of concept trial in animal models.

Parameter Variables Score
Appearance of peri-implant region Normal 0
Slight surface irregularity 1
Moderate surface irregularity 2
Severe disruption/cracks or irregularities 3
Irregularity with associated complications like suppuration, pus, abscess etc. 4
Discolouration of the implant bone interface with no movement of implant. Absence of discolouration 0
Slight discolouration 1
Moderate discolouration 2
Severe discolouration 3
Discolouration with associated complications like suppuration, pus, abscess etc. 4
Presence of distinguished surface mass /hyperplastic growth at the implant bone interface Absence of hyperplastic growth 0
Slight hyperplastic growth 1
Moderate hyperplastic growth 2
Severe hyperplastic growth 3
Hyperplastic growth with associated complications like suppuration, pus, abscess etc. 4
Peri-implant bone radiolucency Absence 0
Slight 1
Moderate 2
Severe 3
Movement of implant Absence 0
Slight 1
Moderate 2
Severe 3