TABLE 2.
Global Intensity Decay Analysis of LysoSensor Probesa
| LysoSensor | pH | α1b | α2b | α3b | f1b | f2b | f3b | 〈τ〉 |
|---|---|---|---|---|---|---|---|---|
| DND-167 | 4.2 | 1.000 | 0.000 | 0.000 | 1.000 | 0.000 | 0.000 | 11.4 |
| 5.7 | 0.651 | 0.215 | 0.134 | 0.894 | 0.100 | 0.006 | 10.6 | |
| 6.3 | 0.436 | 0.304 | 0.260 | 0.797 | 0.189 | 0.014 | 9.8 | |
| 6.9 | 0.144 | 0.471 | 0.385 | 0.457 | 0.508 | 0.035 | 7.2 | |
| τ1 = 11.4 ns, τ2 = 3.9 ns, τ3 = 0.3 ns, = 7.2c | ||||||||
| DND-153 | 4.3 | 1.000 | 0.000 | 1.000 | 0.000 | 6.4 | ||
| 7.5 | 0.838 | 0.162 | 0.979 | 0.021 | 6.2 | |||
| 8.2 | 0.588 | 0.412 | 0.927 | 0.073 | 5.9 | |||
| 8.8 | 0.329 | 0.671 | 0.814 | 0.186 | 5.3 | |||
| 9.4 | 0.106 | 0.894 | 0.515 | 0.485 | 3.6 | |||
| τ1 = 6.4 ns, τ2 = 0.7 ns, = 6.4c | ||||||||
| DND-189 | 3.1 | 0.000 | 1.000 | 0.000 | 0.000 | 1.000 | 0.000 | 4.1 |
| 3.7 | 0.577 | 0.422 | 0.001 | 0.651 | 0.349 | 0.000 | 5.1 | |
| 4.1 | 0.857 | 0.126 | 0.017 | 0.898 | 0.096 | 0.006 | 5.4 | |
| 4.4 | 0.990 | 0.009 | 0.001 | 0.993 | 0.007 | 0.000 | 5.6 | |
| 5.2 | 0.999 | 0.000 | 0.001 | 1.000 | 0.000 | 0.000 | 5.6 | |
| 5.7 | 0.908 | 0.000 | 0.092 | 0.968 | 0.000 | 0.032 | 5.5 | |
| 6.8 | 0.509 | 0.000 | 0.491 | 0.758 | 0.000 | 0.242 | 4.7 | |
| τ1 = 5.6 ns, τ2 = 4.1 ns, τ3 = 1.8 ns, = 7.0c | ||||||||
| DND-189 | 5.2 | 0.970 | 0.030 | 0.000 | 0.996 | 0.004 | 0.000 | 6.4 |
| 5.7 | 0.537 | 0.142 | 0.321 | 0.679 | 0.024 | 0.297 | 5.8 | |
| 6.1 | 0.141 | 0.365 | 0.494 | 0.256 | 0.089 | 0.655 | 4.8 | |
| 6.5 | 0.076 | 0.546 | 0.378 | 0.179 | 0.173 | 0.648 | 4.4 | |
| 6.8 | 0.048 | 0.706 | 0.246 | 0.149 | 0.295 | 0.556 | 3.8 | |
| 7.2 | 0.013 | 0.864 | 0.123 | 0.059 | 0.532 | 0.409 | 2.8 | |
| 7.5 | 0.000 | 0.903 | 0.097 | 0.000 | 0.632 | 0.368 | 2.3 | |
| τ1 = 6.4 ns, τ2 = 0.9 ns, τ3 = 4.7 ns, c | ||||||||
| DND-160d | 2.2 | 1.000 | 0.000 | 1.000 | 0.000 | 2.4 | ||
| 2.7 | 0.871 | 0.129 | 0.956 | 0.044 | 2.3 | |||
| 3.0 | 0.627 | 0.373 | 0.846 | 0.154 | 2.1 | |||
| 3.7 | 0.356 | 0.644 | 0.643 | 0.357 | 1.8 | |||
| 4.3 | 0.167 | 0.833 | 0.395 | 0.605 | 1.4 | |||
| 6.1 | 0.112 | 0.888 | 0.291 | 0.709 | 1.2 | |||
| τ1 = 2.4 ns, τ2 = 0.7 ns, = 2.3c | ||||||||
The average lifetime of LysoSensor DND-192 (λex = 365 nm, λem = 450 ± 20 nm) is 12 ns at either acidic (pH 4.3) or basic (pH 8.8) buffers.
The amplitudes and fractional intensities are normalized to unity.
The accuracies of phase angle and modulation for the instrumentation were 0.3° and 0.008, respectively.
The average lifetimes of LysoSensor DND-160 (λex = 350 nm, λem = 535 ± 25 nm) is 2.37 ns at either acidic (pH 3.0) or basic (pH 8.1) buffers.