Skip to main content
. 2019 Nov 11;10(12):6204–6226. doi: 10.1364/BOE.10.006204

Table 6. Performance of the 3 ensembling binary classifiers at the B-scan level.

CNV vs NORMAL DME vs NORMAL DRUSEN vs NORMAL
Accuracy (95% CI) 0.983 (0.981–0.985) 0.988 (0.987–0.989) 0.978 (0.976–0.980)
Sensitivity (95% CI) 0.984 (0.981–0.987) 0.986 (0.984–0.988) 0.981 (0.980–0.982)
Specificity (95% CI) 0.993 (0.992–0.994) 0.991 (0.990–0.992) 0.986 (0.984–0.998)
AUC (95% CI) 0.997 (0.996–0.998) 0.996 (0.995–0.997) 0.993 (0.991–0.995)

CI: confidence interval; CNV: choroidal neovascularization; DME: diabetic macular edema; AUC: area under receiver operating characteristic curve.