Skip to main content
. Author manuscript; available in PMC: 2020 Oct 1.
Published in final edited form as: J Biomed Inform. 2019 Aug 27;98:103265. doi: 10.1016/j.jbi.2019.103265

Table 4:

Evaluation Results for Concept Type and Boundary Recognition.

EEG Activity EEG Event Medical Problem
Model Precision Recall F1 Precision Recall F1 Precision Recall F1




LSTM 0.8949 0.8125 0.8517 0.8842 0.8301 0.8563 0.8391 0.7863 0.8118
SACAR-V 0.8352 0.8336 0.8344 0.8068 0.8170 0.8119 0.6992 0.6159 0.6549
SACAR-U 0.8494 0.9153 0.8811 0.8335 0.8674 0.8501 0.7658 0.7516 0.7586
SACAR-A 0.9460 0.9080 0.9266 0.9072 0.8299 0.8668 0.8866 0.8358 0.8605
Treatment Test All Types (Macro Average)
Model Precision Recall F1 Precision Recall F1 Precision Recall F1




LSTM 0.9257 0.8687 0.8963 0.8904 0.9250 0.9074 0.8869 0.8645 0.8756
SACAR-V 0.8072 0.7540 0.7797 0.8207 0.8654 0.8425 0.7937 0.7772 0.7854
SACAR-U 0.9332 0.9048 0.9188 0.8171 0.9470 0.8773 0.8398 0.8772 0.8581
SACAR-A 0.9511 0.8814 0.9149 0.9050 0.9280 0.9164 0.9192 0.8766 0.8974