Skip to main content
. 2019 Dec 10;2019:8640893. doi: 10.1155/2019/8640893

Table 2.

Equations of head loss (J, m·m−1) as a function of flow rate (Q, m3·s−1) for Turbo Tape (TT, ξ = 150 μm) and Silver Drip (SD, ξ = 200 μm).

Emitting pipe model Test pressure (kPa) R e range Equation R 2
TT 40 4818 to 17383 J = 287455.85Q1.75 0.9984
TT 60 6454 to 23177 J = 282964.87Q1.75 0.9977
TT 80 6887 to 29092 J = 281889.13Q1.75 0.9991
TT 100 12741 to 32855 J = 279015.61Q1.75 0.9983
SD 40 6275 to 15337 J = 289183.70Q1.75 0.9993
SD 60 8947 to 22490 J = 288884.16Q1.75 0.9988
SD 80 11731 to 27427 J = 288696.89Q1.75 0.9997
SD 100 7954 to 31414 J = 287183.70Q1.75 0.9994