Skip to main content
. 2019 Nov 29;12(23):3962. doi: 10.3390/ma12233962

Table 3.

Relative resistance deviation of MWCNT/epoxy patterned composite strain sensor under cyclic temperature change.

Temperature (°C) Resistance (×MΩ) Measurement Interval (h) Temperature (°C) Resistance (×MΩ) Measurement Interval (h)
30 247.8 0 30 251.1 24
40 252.4 2 40 256.5 2
50 255.8 2 50 260.3 2
60 259.1 2 60 263.8 2
70 260.3 2 70 263.0 2
80 260.0 2 80 262.1 2
30 254.8 24