Mesh sensitivity analysis for the maximum pressure difference ΔPmax across the CA (presented in Pa)

Test subject Coarsest mesh Intermediate mesh Finest mesh
1 66.0 65.9 66.4
2 18.2 18.6 18.3
3 25.2 20.9 19.6
4 23.2 19.8 19.7
5 38.9 34.5 35.2

Coarsest, intermediate and finest corresponded to mesh elements roughly of the order 105, 4 × 105 and 106, respectively. The intermediate mesh was the one chosen for the main analysis