Table 3.
Formulations | Processing Temperature |
Screw Speed |
Barrel Torque |
P-CO2 Injection |
P-CO2 (PSI) |
Back Pressure |
Feeding Zone |
HME Process |
||
---|---|---|---|---|---|---|---|---|---|---|
(°C) | (rpm) | (%) | Zone |
Blockage | ||||||
4 | 6 | 8 | ||||||||
100% HPMC-AS LG | 140 | 100 | Maximum * | - | - | - | - | - | - | Failed |
100% HPMC-AS LG | 140 | 75 | Maximum | - | - | - | - | - | - | Failed |
100% HPMC-AS LG | 140 | 100 | Maximum | √ | √ | - | - | High | - | Failed |
100% HPMC-AS LG | 140 | 75 | Maximum | √ | √ | - | - | High | - | Failed |
100% HPMC-AS LG | 150 | 100 | Maximum | - | - | - | - | - | - | Failed |
100% HPMC-AS LG | 150 | 75 | Maximum | - | - | - | - | - | - | Failed |
100% HPMC-AS LG | 150 | 100 | Maximum | √ | √ | - | - | High | - | Failed |
100% HPMC-AS LG | 150 | 75 | Maximum | √ | √ | - | - | High | - | Failed |
100% HPMC-AS LG | 160 | 100 | 98H.TQ | √ | √ | - | - | High | - | Successful** |
100% HPMC-AS LG | 160 | 75 | 88H.TQ | √ | √ | - | - | High | - | Successful** |
100% HPMC-AS LG | 170 | 100 | 88-90H.TQ | √ | √ | - | - | High | - | Successful** |
100% HPMC-AS LG | 170 | 75 | 82H.TQ | √ | √ | - | - | High | - | Successful** |
100% HPMC-AS LG | 190H.T | 100 | 84-92H.TQ | √ | √ | - | - | High | - | Successful** |
100% HPMC-AS LG | 190H.T | 75 | 80-90H.TQ | √ | √ | - | - | High | - | Successful** |
100% HPMC-AS LG | 190H.T | 100 | 84-92H.TQ | - | - | √ | 300-400 | Low | No | Successful** |
100% HPMC-AS LG | 190H.T | 75 | 80-90H.TQ | - | - | √ | 300-400 | Low | No | Successful** |
80% HPMC-AS LG/% 20 EFA | 140 | 100 | 54 | - | - | - | - | - | - | Successful |
70% HPMC-AS LG/% 30 EFA | 140 | 100 | 46 | - | - | - | - | - | - | Successful |
60% HPMC-AS LG/% 40 EFA | 140 | 100 | 33 | - | - | - | - | - | - | Successful |
50% HPMC-AS LG/% 50 EFA | 140 | 100 | 27 | - | - | - | - | - | - | Successful |
80% HPMC-AS LG/% 20 EFA | 150 | 75 | 44 | - | - | - | - | - | - | Successful |
70% HPMC-AS LG/% 30 EFA | 150 | 75 | 25-30 | - | - | - | - | - | - | Successful |
60% HPMC-AS LG/% 40 EFA | 150 | 75 | 20-25 | - | - | - | - | - | - | Successful |
50% HPMC-AS LG/% 50 EFA | 150 | 75 | 13-20 | - | - | - | - | - | - | Successful |
80% HPMC-AS LG/% 20 EFA | 140 | 100 | 54 | - | - | √ | 300-400 | Low | No | Successful |
70% HPMC-AS LG/% 30 EFA | 140 | 100 | 46 | - | - | √ | 300-400 | Low | No | Successful |
60% HPMC-AS LG/% 40 EFA | 140 | 100 | 33 | - | - | √ | 300-400 | Low | No | Successful |
50% HPMC-AS LG/% 50 EFA | 140 | 100 | 27 | - | - | √ | 300-400 | Low | No | Successful |
80% HPMC-AS LG/% 20 EFA | 150 | 75 | 44 | - | - | √ | 250-350 | Low | No | Successful |
70% HPMC-AS LG/% 30 EFA | 150 | 75 | 25-30 | - | - | √ | 250-350 | Low | No | Successful |
60% HPMC-AS LG/% 40 EFA | 150 | 75 | 20-25 | - | - | √ | 250-350 | Low | No | Successful |
50% HPMC-AS LG/% 50 EFA | 150 | 75 | 13-20 | - | - | √ | 250-350 | Low | No | Successful |
The motor load reached the maximum level in which it was impossible to move on.
Very limited success to obtain the final product, but with very high motor load and high temperature.
H.T: Very high temperature.
H.TQ: Very high motor load (High Torque).