Maximum relative error % between EncephaLog biomarkers and biomarkers from each of the three technologies used (top row—Android, bottom row—iOS). (-) Marks biomarkers that could not be derived from the pressure mat.

Motion Capture Cameras n = 17 Pressure Mat n = 15 Wearable Sensors n = 15
Completion Time (s) 11.192 - 4.959
7.930 - 2.737
Stand-Up Time (s) 21.324 - 7.957
20.956 - 5.263
Walk-Away Time (s) 21.313 - 6.381
16.794 - 1.725
Rotation Time (s) 34.112 - 13.302
37.617 - 6.400
Walk-Back Time (s) 32.904 - 3.896
28.860 - 3.506
Sit-Down Time (s) 22.203 - 10.961
15.734 - 8.511
Rotation Steps (#) 50.000 - 20.000
50.000 - 0.000
Walking Steps (#) 40.450 22.124 18.771
41.466 16.628 2.258
AVG. Steps Frequency (Cadence) (#/s) 49.564 7.204 4.996
50.646 3.874 2.500
AVG. Steps Length (m) 19.586 13.308 6.627
17.347 14.159 2.256