Table 2.

Differences between T‐Wave Alternans (TWA) Profiles of Healthy Subjects and Implantable Cardioverter‐Defibrillator (ICD) Patients as Depicted in the Measured Variables and Distinctive Features

Features Healthy Subjects (N = 31) ICD Patients (N = 33)
Age (years) 36 ± 9 50 ± 18
(18–55) (15–73)a
Max TWA at rest (μV)  1 ± 2 8 ± 9
(0–5)  (0–38)a
Max TWA during test (μV)  26 ± 13 37 ± 20
(4–61) (7–101)b
Heart rate (HR) at max 118 ± 8  90 ± 17
 TWA during test (bpm) (92–127) (61–126)a
HR at rest (bpm)  79 ± 10 67 ± 15
(62–98) (47–99)a

All variables displayed in mean ± SD (minimum – maximum).

aP < 0.001 compared to healthy subjects (Mann‐Whitney test).

bP = 0.009 compared to healthy subjects (Mann‐Whitney test).