Table 1.

Correlations of Manually and Automatically Generated HRV Measures Using Two Different Approaches

Manual versus Autoa Manual versus Auto 2b
HRV Measure R P‐Value R P‐Value
DCT1 0.903 <0.001 0.371 <0.001
DCT5 0.980 <0.001 0.427 <0.001
SDNN 0.653 <0.001 0.294 0.003
RMSSD 0.761 <0.001 0.208 0.038
LF 0.278 0.005 0.148 0.145
HF 0.603 <0.001 0.105 0.304
a

Auto refers to automatic R‐peak detection as proposed in the present study mainly based on a Shannon entropy envelope estimator and a subsequent Hilbert transformation;

b

Auto 2 refers to a standard R‐peak identification based on the Pan–Tompkins algorithm.

Abbreviations as in text.