Skip to main content
. 2007 Jun 6;12(2):89–97. doi: 10.1111/j.1542-474X.2007.00146.x

Table 4.

Diagnostic Test Characteristics for Detecting Left Ventricular Dysfunction Using Systolic Time Intervals and B‐Type Natriuretic Peptide Levels

Sensitivity Specificity + LR − LR Accuracy
EMAT ≥ 15  44 (22–69) 94 (85–98)  7.0 0.59 0.83
EMAT/LVST ≥ 0.40  56 (31–78) 95 (87–99) 11.7 0.47 0.86
BNP ≥ 100 pg/mL 100 (80–100) 57 (44–70)  2.3 0 0.66
BNP ≥ 250 pg/mL  94 (71–100) 79 (67–89)  4.6 0.07 0.83
BNP ≥ 500 pg/mL  59 (33–82) 94 (85–98)  9.3 0.44 0.86

EMAT = electromechanical activation time; LVST = left ventricular ejection time; BNP = B‐type natriuretic peptide.