Skip to main content
. Author manuscript; available in PMC: 2019 Dec 27.
Published in final edited form as: Med Image Comput Comput Assist Interv. 2019 Oct 10;11768:336–344. doi: 10.1007/978-3-030-32254-0_38

Table 1.

Prediction accuracy evaluation of three different simulation methods using surface deviation error. * Significantly greater than 1 mm (P<0.05), ** Significant improvement compared with Method #1 and #2.

Prediction method Improvement over
Method #2 (%)
Region Method#1 Method#2 Our approach
Upper lip 1.11 0.99 0.84 14
Lower lip 1.53* 1.57* 0.85** 46**