Skip to main content
. 2018 Oct 31;63(1):34–44. doi: 10.1093/annweh/wxy089

Table 2.

Concentration of RCS and RD during chipping tasks ‘with’ and ‘without’ the air curtain.

Task/control used n a Sampling duration (hours) Respirable silica conc. (µg/m3) Respirable dust conc. (µg/m3) % of samples with RCS conc. > OSHA PEL of 50 µg/m3
GM (GSD) Range GM (GSD) Range
Chipping/without air curtain 19 72–318 590 (2.02) 152–1553 5980 (1.55) 240–17,511 100%
Chipping/with air curtain 12 54–168 440 (1.55) 101–1343 330 (2.54) 470–19,525 100%

a n = Number of samples collected.