Table 4.

Changes in blood pressure and heart rate over the observation period

Catheter AVFAVG SMD
N 798 399
Systolic blood pressure (mm Hg)
 Baseline 143.5 (17.8) 143.0 (14.0) 0.032
 6 months 144.6 (17.2) 142.6 (16.5) 0.118
 12 months 144.6 (19.3) 141.3 (16.5) 0.184
Change over 6 months 1.1 (17.5) –0.4 (17.2) 0.084
 Change over 12 months 1.1 (21.2) –1.7 (17.0) 0.146
Diastolic blood pressure (mm Hg)
 Baseline 76.4 (11.7) 76.3 (10.4) 0.008
 6 months 75.9 (11.2) 72.3 (11.1) 0.327
 12 months 75.8 (11.7) 72.4 (11.2) 0.297
 Change over 6 months –0.4 (9.5) –3.7 (8.7) 0.365
 Change over 12 months –0.6 (11.1) –3.9 (9.0) 0.328
Heart rate (beats per minute)
 Baseline 73.8 (12.0) 71.0 (9.9) 0.248
 6 months 72.2 (11.9) 70.1 (10.6) 0.187
 12 months 75.3 (11.4) 72.1 (10.8) 0.29
 Change over 6 months –1.0 (9.7) 0.1 (10.4) 0.114
 Change over 12 months 1.5 (11.8) 0.9 (9.9) 0.052

Abbreviations: AVF: arteriovenous fistula; AVG: arteriovenous graft.