Table 2. Performance of different cut-offs of GA and HbA1c to diagnose DM by OGTT. (n = 242).

Threshold Sensitivity (%) Specificity (%) LR+ LR-
GA (%) 13.0 93.5 15.2 1.10 0.43
14.0 84.4 44.2 1.51 0.35
14.8 64.9 65.5 1.88 0.54
15.0 62.3 69.7 2.06 0.54
15.5 48.1 77.6 2.14 0.67
16.0 42.9 84.8 2.83 0.67
16.6 36.4 90.3 3.75 1.41
16.8 31.2 93.3 4.68 0.74
17.0 29.9 93.9 4.93 0.74
17.5 20.8 96.4 5.71 0.82
HbA1c (%) [mmol/mol] 5.5 (37.0) 87.0 58.2 2.08 0.22
5.7 (39.0) 81.8 68.5 2.59 0.27
5.8 (40.0) 76.6 72.7 2.81 0.32
6.00 (42.) 61.0 82.4 3.47 0.47
6.5 (48.0) 31.2 93.3 4.68 0.74
6.8 (51.0) 22.1 98.2 12.14 0.79

DM, Type 2 diabetes mellitus; HbA1c, glycated haemoglobin; GA, glycated albumin; LR, likelihood ratio; OGTT, oral glucose tolerance test.