Skip to main content
. 2019 Dec 23;378(2164):20190160. doi: 10.1098/rsta.2019.0160

Table 1.

Energy measurements from 24-board SpiNNaker system used to execute cortical microcircuit simulations.

configuration wall-clock time total energy (kWh) synaptic events energy per synaptic event (μJ/syn-event)
system only 12 h 0.93
12 booted boards 12 h 4.93
cortical microcircuit, DC input, real-time 12 h 6.59
cortical microcircuit, Poisson input, real-time 12 h 7.11
cortical microcircuit, DC input, real-time 10 s 0.001525a 9.135 × 109 0.601
cortical microcircuit, Poisson input, real-time 10 s 0.001646a 9.343 × 109 0.628

aQuantity estimated from extended duration simulation.