Skip to main content
. 2019 Dec 26;6:100040. doi: 10.1016/j.wroa.2019.100040

Table 1.

Operational conditions of the two treatment systems (CAS and AGS) at the Vroomshoop and Garmerwolde WWTPs during the sampling campaign - December 2017 to May 2018.

Parameters Vroomshoop
Garmerwolde
CAS AGS CAS AGS
Average Dry flow (ADF) (m3/d) 2140 1541 27,645 20,355
Average peak flow (m3/h) 1125 140 7148 4200
Population equivalent COD based 13,100 9500 210,000 140,000
Organic loading rate (kg COD/m3/d) (aerated) 0.50 0.65 0.53 0.50
Mixed liquor suspended solids range (g/m3) 3–6 9–14 5–8 10–14
Aerated basin, O2 (g/m3) 0.3–1.8 1.5–2.8 1.0–2.0 0.2–2.4
Water temperature (C) range 8.5–17.8 8.5–17.8 8.6–18.0 8.6–8.0
Hydraulic retention time (HRT) at ADF(h) 27 11–24 24 10–12
Sludge retention time (d) 27 >21 23 >30