Skip to main content
. 2019 Dec 13;23(1):100774. doi: 10.1016/j.isci.2019.100774

Figure 2.

Figure 2

The Electrochemical and ECL Performances of the Polymers and PNs

(A) CVs of 0.5 mM P1 and P2 in Bz:MeCN (v:v = 1:1) containing 0.1 M TBAPF6 as the supporting electrolyte with scan rate of 0.1 V/s.

(B) ECL intensity-potential profiles of 20 μM P1 and P2 in THF containing 0.1 M TBAPF6 as supporting electrolyte, upon addition of 75 mM TPrA as co-reactant.

(C) ECL intensity-potential profiles of 20 μM PNs-1 and PNs-2 in water containing 0.1 M LiClO4 as the supporting electrolyte, upon addition of 75 mM TPrA as co-reactant.

(D) ECL intensity-time curves of 20 μM PNs-2 and Ru(bpy)32+ in water containing 0.1 M LiClO4 as the supporting electrolyte with 75 mM TPrA as the co-reactant. PMT = 500 V.

See also Figures S13 and S14.