Figure 5.

Figure 5.

(a) Representative in vitro PA images showing improved PA signal for CRaB compounds vs analogous unrestricted aza-BODIPY dyes at their corresponding PA maxima. (b) Correlations between in vitro PA signal vs extinction coefficient or (c) PABF for all 12 compounds listed in Table 3.