Skip to main content
. 2019 Dec 23;2019:2018598. doi: 10.1155/2019/2018598

Table 4.

Comparison of reference intervals for myocardial enzyme activity applied with similar detection systems and/or methodologies.

This study Other country research Cao et al. [29]
System/method Age Sex RI System/method Age Sex RI System/method Age Sex RI
AST (U/L) VITROS 5600/multipoint rate 1∼<7 M + F 22.7–51.9 VITROS 5600/rate [30] 1∼<7 M + F 33–66 VITROS 350/rate 3 m∼<3 y M + F 23–60
7∼<12 M 18.2–36.4 7∼<12 M + F 28–50 3 y∼<12 y M + F 24–47
F 16.0–33.8 12∼<18 M 24–49 12∼<18 M + F 17–47
12∼<18 M 15.4–33.3 F 23–41
F 13.7–26.6

LDH (U/L) VITROS 5600/multipoint rate 1∼<7 M + F 434.9–737.7 Abbott ARCHITECT/rate [30] 1∼<10 M + F 309–1222 VITROS 350/rate 3 m∼<3 y M + F 504–896
7∼<12 M 408.8–663.7 10∼<15 M + F 163–452 3 y∼<12 y M + F 491–790
F 373.8–642.1 15∼<19 M + F 192–321 12∼<18 M + F 342–716
12∼<15 M 364.8–641.0
15∼<18 M 314.6–568.6
12∼<18 F 315.7–554.9

CK (U/L) VITROS 5600/multipoint rate 1∼<18 M 49.1–194.1 VITROS/rate [31] 13∼24 m M 27–160 VITROS 350/rate 3 m∼<12 y M + F 50–226
1∼<7 F 41.0–166.5 F 24–175 12 y∼<18 y M 47–256
7∼<12 F 39.3–155.4 2∼14 M 30–150 F 34–235
12∼<15 F 36.6–129.2 2∼10 F 24–175
15∼<18 F 32.0–105.9 11∼14 F 30–170
15∼18 M 33–145
F 27–140

CKMB (U/L) VITROS 5600/multipoint rate 1∼<7 M + F 11.4–38.9 VITROS 350/rate 3 m∼<6 y M + F 18–44
7∼<15 M 7.9–34.2 6 y∼<12 y M + F 7–35
7∼<12 F 7.4–30.7 12 y∼<18 y M + F 7–28
12∼<15 F 2.8–23.3
15∼<18 F 2.7–15.5
15∼<18 M 2.1–20.8

Lowest detection limit. Actual values could be lower.