Skip to main content
. 2019 Nov 25;8(12):586. doi: 10.3390/antiox8120586

Table 4.

Measured and predicted values of the response for every point of the experimental design implemented.

Design Point Independent Variables Response (YTP, mg GAE g−1 dm)
X1 (CDES, % w/v) X2 (RL/S, mL g−1) X3 (SS, rpm) Measured Predicted
1 −1 (55) −1 (20) 0 (500) 93.36 96.63
2 −1 (55) 1 (60) 0 (500) 122.14 124.20
3 1 (85) −1 (20) 0 (500) 115.40 113.34
4 1 (85) 1 (60) 0 (500) 123.72 120.45
5 0 (70) −1 (20) −1 (200) 100.43 99.68
6 0 (70) −1 (20) 1 (800) 118.23 117.77
7 0 (70) 1 (60) −1 (200) 123.19 123.65
8 0 (70) 1 (60) 1 (800) 127.72 128.47
9 −1 (55) 0 (40) −1 (200) 102.00 99.48
10 1 (85) 0 (40) −1 (200) 113.00 115.81
11 −1 (55) 0 (40) 1 (800) 123.60 120.79
12 1 (85) 0 (40) 1 (800) 114.90 117.42
13 0 (70) 0 (40) 0 (500) 116.25 115.32
14 0 (70) 0 (40) 0 (500) 115.00 115.32
15 0 (70) 0 (40) 0 (500) 114.72 115.32