Table 5. The performance of the deep learning system vs. general ophthalmologists in detecting notable peripheral retinal lesions.
Item | Sensitivity (95% CI), % | Specificity (95% CI), % | Accuracy (95% CI), % |
---|---|---|---|
Ophthalmologist A | 93.6 (89.6–97.6) | 98.7 (97.8–99.6) | 97.6 (96.5–98.7) |
Ophthalmologist B | 85.9 (80.0–91.8) | 96.8 (95.4–98.2) | 94.5 (92.8–96.2) |
Deep learning system | 98.7 (96.9–100) | 99.2 (98.5–99.9) | 99.1 (98.4–99.8) |
CI, confidence intervals; A, the general ophthalmologist with 5-year working experience in physical examination center; B, the general ophthalmologist with 3-year working experience in physical examination center.