Skip to main content
. 2019 Dec 12;12(24):4181. doi: 10.3390/ma12244181

Table 6.

Parameters for DSCs using electrolytes based on imidazolium ionic liquids with different counterions. Data for multiple DSCs are given in Table S5 in the Supporting Information.

Electrolyte 1,2 JSC/mA cm−2 VOC/mV ff/% η/% Rel. η/% 3
BDMIBF 3.80 266 41 0.41 7.3
BDMIPF 2.84 351 58 0.57 10.2
BDMICFSO 2.22 385 66 0.56 10.0
PMIBF 4.90 244 30 0.35 6.3
PMINCFSO 2.84 316 62 0.56 10.0
PMII c 3.01 315 62 0.59 10.5
Reference cell with dye N719 12.53 654 68 5.60 100

1 The electrolyte compositions are LiI (0.18 M), I2 (0.05 M), and IL (0.6 M) in MPN. 2 Data for PMIIc and BMIIc are repeated from Table 2 for convenience. 3 All DSCs are referenced to N719 sensitized DSC. Relative efficiencies are given with N719 PCE set to 100% [61].