Skip to main content
. 2020 Jan 8;8(1):E76–E80. doi: 10.1055/a-1012-1838

Table 1. Baseline patent characteristics.

Complete closure Simple closure P value
Patient
  • Number

15 19
  • Male:female

8:7 9: 0 1
  • Age

65.8 ± 11.1 72.9 ± 10.2 0.06
Complications during ESD 0.353
  • Perforation during ESD

8 6
  • Muscular layer injury

7 13
Resected specimen
  • Size

31.6 ± 8.65 38 ± 10.4 0.06
Location 0.10
  • Cecum

1 4
  • Ascending colon

4 3
  • Transverse colon

4 4
  • Descending colon

0 3
  • Sigmoid colon

3 0
  • Rectum

3 5
Operator
  • Experts (> 50 ESD cases)

8 12 0.82
  • Non-experts (< 50 ESD cases)

7 7