Table 1.
Protocol | Sequences | Duration |
---|---|---|
Shunt | Coronal T2 SSFSE | 7 min |
Sagittal T2 SSFSE | ||
Axial T2 SSFSE | ||
Axial 3D SWAN | ||
Abusive head trauma screen | Axial DWI | 16 min |
Axial GRE | ||
Axial T2 Propeller | ||
Coronal T1 FLAIR | ||
Axial 3d SWAN | ||
Axial fast FLAIR | ||
Axial T2 SSFSE | ||
Stroke | Axial DWI | 22 min |
3D ASL | ||
Axial T2 FLAIR | ||
Axial 3D SWAN | ||
3D Time-of-flight 3-slab MRA | ||
Neurologic | DWI | 7 min |
Axial GRE | ||
Axial T2 SSFSE | ||
Axial T2 FLAIR | ||
Sagittal T1 FSPGR |
SSFSE single-shot fast spin-echo sequence, SWAN Susceptibility-weighted angiography, DWI Diffusion-weighted magnetic resonance imaging, GRE gradient echo, FLAIR Fluid-attenuated inversion recovery, ASL arterial spin labeling, MRA magnetic resonance angiography, FSPGR fast spoiled gradient echo. Protocol durations include the localizer time