Skip to main content
. 2009 Dec 14;25(2):356–361. doi: 10.1359/jbmr.090803

Table 1.

Descriptive Statistics of Measured Parameters

Mean ± SD Range
DXA measurements
 BMC (g) 6.6 ± 1.69 2.96–9.68
 BMD (g/cm2) 0.62 ± 0.11 0.36–0.80
 vBMD (g/cm3) 0.13 ± 0.03 0.06–0.20
µCT measurements
 BV/TV (%) 15.31 ± 5.05 7.17–25.85
 Tb.Th (µm) 224 ± 44 160–330
 DA (n) 0.44 ± 0.04 0.36–0.51
 SMI (n) 1.83 ± 0.24 1.26–2.25
 Ct.Th (µm) 641 ± 400 206–1983
 Ct.Curv (mm) 33 ± 15 12–70
Mechanical tests
 Failure load (N) 2644 ± 1012 651–5481
 Compressive stiffness (N/mm) 3072 ± 1545 663–6741
 Work to failure (N/mm) 1640 ± 978 453–4158

DXA = dual energy X‐ray absorptiometry; BMC = bone mineral content; BMD = bone mineral density; vBMD = volumetric bone mineral density; µCT = micro‐computed tomography; BV/TV = bone volume/tissue volume; Tb.Th = trabecular thickness; DA = degree of anisotropy; SMI = structure model index; Ct.Th = anterior cortical thickness; Ct.Curv = anterior cortical radius of curvature.