Table 3.
Reproducibility of automated methods on 10 subjects per dataset. From left to right, the table lists median [1st and 3rd quartiles] for volumes; mean ± std for volumes; p values for the pairwise comparison of volumes from first and second time processed full images; ICC (absolute agreement (lower-upper band of 95% CI)) between volumes from full and FFR-processed images; and Dice’s similarity index between segmentation from first and second time processed full images
| N = 10 | Volume | p value | ICC | SI | ||
|---|---|---|---|---|---|---|
| AD NBV (L) | First | 1.34 [1.29; 1.38] | 1.32 ± 0.10 | |||
| Second | 1.34 [1.30; 1.40] | 1.34 ± 0.07 | 0.30 | 0.988 (0.973–0.992) | ||
| AD BV (L) | First | 1.09 [1.00; 1.13] | 1.06 ± 0.13 | |||
| Second | 1.08 [1.30; 1.40] | 1.07 ± 0.14 | 0.35 | 0.998 (0.992–1.000) | ||
| MS LV (mL) | First | 3.00 [1.64; 8.08] | 6.39 ± 6.87 | |||
| Second | 3.82 [2.11; 8.35] | 6.68 ± 6.74 | 0.16 | 0.996 (0.971–0.999) | 0.95 [0.84–0.98] | |
| GB GBV (mL) | First | 39.89 [25.11; 85.92] | 68.50 ± 69.66 | |||
| Second | 40.65 [25.28; 86.61] | 69.38 ± 70.16 | 0.06 | 0.998 (0.998–1.000) | 0.94 [0.89–0.96] | |
ICC, intra-class correlation coefficient; N = amount of subjects; std, standard deviation; AD, Alzheimer’s disease; MS, multiple sclerosis; SI, Dice’s similarity index; FN, false negative; FP, false positive