Skip to main content
. 2020 Jan 1;209(1):107402. doi: 10.1016/j.jsb.2019.10.004

Table 1.

Dataset and data collection details. *K2 summit direct electron detector from Gatan Inc. CA, USA. DE20 direct electron detector from Direct Electron, San Diego, CA. With quantum post-column energy-filter (Gatan Inc. CA, USA), operated in zero-loss imaging mode with a 20-eV energy-selecting slit. §C-Flat 2/2-4C from Protochips Inc. Lacey carbon grids from Agar Scientific.

Decorator Tubulin Ligands Grid type EM and energy filtration Detector and mode Pixel size (Å/pixel) Defocus range Dose (e-/Å2, weighted) Total exposure time and frame number EMPIAR and EMDB accession codes
CKK domain of CAMSAP1 α-tubulin: GTP
β-tubulin: GDP, Taxol
2 μm Holey Carbon§ Polara (300 kV) K2 summit* Counting at 5e-/pixel/sec 1.39 0.5–3.5 μm 42 dose weighted 16 secs 64 frames EMPIAR-465
EMD-4643
Motor domain of MKLP2 α-tubulin: GTP
β-tubulin: GDP, Taxol
2 μm Holey Carbon§ Polara (300 kV) DE20 (Direct Electron)
Linear
1.53 0.5–3.0 μm 50 dose weighted 1.5 secs
22 frames
EMPIAR-467
EMD-10131
N-DC domain of DCX α-tubulin: GTP
β-tubulin: GDP
Lacey Carbon Polara (300 kV) K2 summit*
Counting at 5e-/pixel/sec
1.39 0.5–2.5 μm 24 unweighted 9 secs
36 frames
EMPIAR-10300
EMD-10195