Skip to main content
. 2020 Jan 15;15:12. doi: 10.1186/s11671-020-3247-9

Table 1.

A comparative study between the suggested immobilized CQDs/ZnO-BM 19.21 nanocomposite fluorescence immunosensing technique and previously published techniques

Technique Principle Linear concentration range, ng mL−1 Lower limit of detection, ng mL−1 References
Enzyme immunoassay Enzyme immunoassay method using Boehringer Mannheim (Enzymun-Test CYFRA 21-1) in the serum 3.2–11.5 3.5 [5]
Electro-chemiluminescence immunoassay The ability of an electrochemically luminescent molecule, a tris(2,2′-bipyridyl) ruthenium (II) complex, to be repeatedly excited by tripropylamine 3.1–10.7 3.0 [6]
Suggested immobilized CQDs/ZnO-BM 19.21 nanocomposite immunosensing system A sandwich capping antibody-antigen-antibody fluorescence immunosensing system of immobilized CQDs/ZnO-BM 19.21 0.01–100 0.008 Present study