Table 4.
Type of SO2 Release and Amount of SO2 in Pads (A) | Stem Browning a | ||
---|---|---|---|
After 30 Days in a Cold Chamber | After 45 Days in a Cold Chamber | After 3 Days at Shelf-Life | |
Slow release—7 g | 1.00 ± 0.00 a | 1.28 ± 0.11 ab | 2.08 ± 0.09 a |
Slow release—4 g | 1.00 ± 0.00 a | 1.30 ± 0.06 a | 2.33 ± 0.07 a |
Dual release—5 g | 1.00 ± 0.00 a | 1.11 ± 0.07 ab | 2.06 ± 0.08 a |
Dual release—8 g | 1.05 ± 0.00 a | 1.05 ± 0.04 b | 2.30 ± 0.08 a |
Ventilation area of perforated plastic liners (B) | |||
0.3% | 1.00 ± 0.00 a | 1.31 ± 0.07 a | 2.10 ± 0.05 b |
0.9% | 1.00 ± 0.00 a | 1.12 ± 0.09 a | 2.40 ± 0.09 a |
1.0% | 1.00 ± 0.00 a | 1.12 ± 0.07 a | 2.08 ± 0.08 b |
Contrast of the additional treatment with the factorial | |||
Additional treatment | 1.05 ± 0.05 a | 1.20 ± 0.08 a | 2.19 ± 0.13 a |
Factorial | 1.00 ± 0.00 a | 1.18 ± 0.08 a | 2.07 ± 0.08 b |
F (A) | 0.14 ns | 3.51 * | 4.29 * |
F (B) | 1.08 ns | 0.80 ns | 8.46 * |
F (A × B) | 0.07 ns | 1.59 ns | 0.55 ns |
F (additional treat. × factorial) | 12.00 ns | 0.01 ns | 18.39 * |
CV % | 27.41 | 21.95 | 13.14 |
Means within columns followed by the same letters are not statistically different as determined by Tukey’s test (* p ≤ 0.05). ns: not significant. CV: coefficient of variation. a Stem browning scores: (1) fresh and green, (2) some light browning, (3) significant browning, and (4) severe browning [14].