Skip to main content
. 2020 Jan 17;10:594. doi: 10.1038/s41598-019-57396-6

Table 3.

Determinations of RBP4 in real (normal and diabetic) male samples by the present aptasensor and ELISA kit. The %CVs for intra- and inter-assay averages are 0.010 and 0.015, respectively.

Normal Male Samples *Present Aptasensor *ELISA
µg/mL
Standard Deviation %CV Diabetic
Male Samples
*Present Aptasensor *ELISA
µg/mL
Standard Deviation %CV
1 25.834 25.839 0.004 0.015 1 36.496 36.491 0.004 0.011
2 24.045 24.043 0.001 0.004 2 33.93 33.926 0.003 0.008
3 22.942 22.945 0.002 0.008 3 39.681 39.678 0.002 0.005
4 27.443 27.455 0.008 0.029 4 33.559 33.555 0.003 0.009
5 27.235 27.231 0.003 0.011 5 35.711 35.709 0.001 0.003
6 27.043 27.038 0.004 0.014 6 39.89 39.892 0.001 0.002
Average 25.693 25.759 0.004 0.015 Average 36.545 35.693 0.002 0.005

*Mean of triplicate measurements.