Skip to main content
. 2020 Jan 2;2020:6745626. doi: 10.1155/2020/6745626

Table 5.

Inter- and intraobserver reliability for fracture involvement determined using six measurement methods.

Examiner Plain radiographs Axial CT linear Sagittal CT linear Axial CT plane 3D CT linear 3D CT surface
Chief-chief 4.66 3.01 3.25 2.37 2.59 2.01
Attending-attending 4.79 3.18 3.62 2.11 2.92 1.91
Resident-resident 7.49 3.13 3.99 2.25 3.11 2.68
Chief-attending 7.49 4.60 4.60 5.28 3.55 1.81
Chief-resident 7.51 5.35 6.28 4.80 3.69 1.98
Attending-resident 5.46 5.59 5.90 5.88 3.75 2.79

Values are presented as standard error of measurement; the larger the standard error of measurement, the lower the reliability.