Skip to main content
. 2019 Dec 19;7:100779. doi: 10.1016/j.mex.2019.100779

Table 2.

The values of the equilibrium swelling Se, the rate parameter r, and the mean squared error MSE obtained using the five different methods for the potassium polyacrylate powders and the sodium polyacrylate powders, respectively.

Hydrogel Sample Parameters Tea-Bag Pyramid Tea-Bag Sieve Filtration Proposed Method
Potassium
polyacrylate
r (s) 227.9 164.4 88.8 87.1 111.0
Se (g/g) 126.0 133.6 142.2 145.6 121.2
MSE 944.7 1156.3 757.3 811.9 243.7
Sodium
polyacrylate
r (s) 281.5 222.4 147.1 116.5 143.8
Se (g/g) 352.5 363.7 377.6 403.4 329.6
MSE 276.4 250.9 50.2 155.2 49.2