Skip to main content
. 2020 Jan 2;13(1):189. doi: 10.3390/ma13010189

Table A4.

The leakage test results of Novachip-B.

Sample Number Mixture Quality (g) Adhesive Quality (g) Leakage Loss (%) Average Leakage Rate (%) Test Temperature (°C)
1 1000.1 0.71 0.07 0.09 185
2 1000.4 0.93 0.09
3 1000.6 1.14 0.11
4 1000.3 0.82 0.08